Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations SSS148 on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by adnan1268

  1. adnan1268

    Body Flange Bolt Spacing

    Thanks D2HANDLE and SnTMan for your reply. Regards Adnan
  2. adnan1268

    Body Flange Bolt Spacing

    Please refer calculation of a body flange given below from PV Elite: ASME Maximum Circumferential Spacing between Bolts per App. 2 eq. (3) [Bsmax]: = 2a + 6t/(m + 0.5) = 2 * 24.000 + 6 * 62.000/(2.00 + 0.5) = 196.800 mm Maximum Bolt Spacing Exceeded ! For vessels in lethal service or...
  3. adnan1268

    Body Flange and Tube Sheet distance

    Dear MJCronin and Racookpe1978, I spoke to client regarding non-standard body flange and got clarification. Thanks for your reply
  4. adnan1268

    Body Flange and Tube Sheet distance

    Hi... I am designing an AJL type R class exchanger. I have two questions 1) When I enter body flange dimensions (this is a non-standard flange) with hub dia and length equal to zero, the software says wrong geometry. 2) There is always a visible gap between body flange and tube sheet and it...