  1. ahmadbazzari

    penstock leakage test

    so ( 0.62 liter / min X m ) X 180 min = 111.6 liter / m then ( 111.6 liter / m ) X ( 0.70 + 0.65 + 0.70 )m = 228.78 liter then convert from liter to cubic meter = 0.22878 m3 so the level decrease = ( 0.22878 m3 / 14.79 m2 ) = 1.5 cm is that right ?
  2. ahmadbazzari

    penstock leakage test

    hi every body , i have a test for gates leakage at 24-Nov-2016 , so i have to prepare the form the equation for allowable leakage is 0.62 liter per ,minute per meter of gate periphery iam really don't know how to deal with it can you help me in calculation to find the level decrease of water...
  3. ahmadbazzari

    valves and fittings (pipeline )

    hi am a fresh graduated mechanical engineer working at " wast water pumping station " put i became some nervous from some welding and pipeline design basic so many questions on my head like .... 1) can we weld two fittings together ? 2) can we weld fittings directly to a valve ? 3) can...