Artisi's latest activity

  • A
    Artisi reacted to LittleInch's post in the thread Diamagnetic Pump with Sad Sad.
    This looks like snake oil to me. It's also not a "pump" in any sense so this probably isn't the right forum. I would try one of the...
  • A
    Following Pierre's comment, discharge pressure changes at the square of the speed change and flow at the ratio of change, this can...
  • A
    Artisi replied to the thread pump and motor.
    Correct, crystal ball gazing and guess work for the want of a bit of useful data.
  • A
    Artisi replied to the thread pump and motor.
    How about you tell us what the operating flow and head is for the system your pumping on. At the moment noboby has a clue as to what is...
  • A
    Artisi replied to the thread pump and motor.
    What duty?, the Q / H stamped on the pump name plate.
  • A
    Artisi replied to the thread pump and motor.
    That results in higher amps.
  • A
    Artisi replied to the thread pump and motor.
    And it's viscosity? It's like squeezing blood out of stone getting usefull data.
  • A
    Artisi replied to the thread pump and motor.
    Igpm or usgpm?
  • A
    Artisi replied to the thread pump and motor.
    Looking at the flow and head on the pump plate, we can assume this is probably performance at its BEP, calculating the power required at...
  • A
    Artisi replied to the thread pump and motor.
    It will be the power required to operate anywhere on its designed performance curve, that will be maximum water horsepower divided by...
  • A
    Artisi replied to the thread pump and motor.
    It's pretty clear what the voltage supply should be, 415v 50 htz as per the motor data plate.
  • A
    Artisi replied to the thread pump and motor.
    Your not using like terms, the pump from India is more than likely Imp gpm and you're using 3960 that is used for USgpm.
  • A
    Artisi replied to the thread pump and motor.
    Or running near to end of the curve requiring in excess of 3.7Kw. It's interesting that it's always the pump or motor at fault, never...
  • A
    Artisi reacted to Snickster's post in the thread pump and motor with Like Like.
    Right, the pump may be operating at the end of curve. I stated such in one of my e-mails above that the actual operating point is not...
  • A
    Artisi replied to the thread pump and motor.
    A lot of these small off the shelf pumps are supplied with motors sized to operate across their performance curve and and more than...