don1980 and EmmanuelTop
Thank you both for your input. To clarify, I was referring to a general procedure for sizing rupture disc.
Quoting 5.11.1.2 Rupture Disk Sizing Using Coefficient of Discharge Method (Kd = 0.62)
5.11.1.2.1 The required discharge area, A, in in^2 (mm2^), can be calculated...
Hello,
BACKGROUND
-need to size Rupture Disk
--nonfire case
--liquid is discharge fluid (BRINE aka salt water)
--vent to atmosphere
--using API 520, 9th edition, July 2014
--able to use the Coefficient of Discharge Method where Kd=0.62
QUESTION
-Section 5.11.1.2.1 says to use Equation 28 to...