Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by ChaseThisLight

  1. ChaseThisLight

    Feedwater Heater Levels and Performance

    Recently we have began to look at the performance of our feedwater heaters, and I have a few questions. We are a 700 Net MW plant, with 2 HP heaters, deaerator, and 4 LP Heaters. For about the past year, one of the LP Heaters was at a very low level. Once we noticed this, we changed the...
  2. ChaseThisLight

    Condensate Pump Possible Issues

    You're amazingly helpful. I truly appreciate all of the help and guidance you have given. I walked down the system with an operator and after that and looking at the P&IDs as well as all the data I have, it looks like the main cause to the issue of steam being created from a blockage in a Y...
  3. ChaseThisLight

    Condensate Pump Possible Issues

    Here is a snapshot of the worst performing pump. It measures flow vs efficiency which I calculated. The black line is the pump curve provided by the manufacturer. Link
  4. ChaseThisLight

    Condensate Pump Possible Issues

    Thanks all for the suggestions. It has been a lot of help. Sorry for delays, I got pulled into another project. Seems like that happens a lot. I should have been more descriptive with my post. When I began looking at this, I spoke with maintenance and operations departments to determine what...
  5. ChaseThisLight

    Condensate Pump Possible Issues

    Hello, I work in a steam generation facility, and am currently having issues with condensate pumps. Forgive my ignorance, I am a recent graduate and don't know much about pumps, or the facility in general. The plant has 3 vertical condensate pumps. Two are in operation at any time, with one as a...

Part and Inventory Search