Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by chinleong

  1. chinleong

    ISO tank IMO7 repair

    TY for your reply but we checked all pipes and connection with helium and all is still good. We done by pressurize annular space with helium+N2. Then purge some N2 to inner vessel for bring out helium detect purpose. That is no signal show on leak detector machine.
  2. chinleong

    ISO tank IMO7 repair

    I'm checking a 5000usg LN2 cryogenic tank. I found out that annular space(vacuum break) will blow out air when i were pressurize inner tank, but there is no leak or crack of inner vessel. Can anyone explain why would this happen?

Part and Inventory Search