The lugs are placed on beams of an existing steel structure, The structure is attached to concrete foundations with full moment connections.
I am saying that the lug to beam connection is pinned considering it only has two bolts per lug in a straight line
Yes, I get that but the loads for...
Hi all,
We are in the process of ordering a Heat Exchanger. The heat exchanger is vertical and supported by two lug supports. The vendor has given us a foundation loads table. In this table the vendor has mention wind/earthquake shear and wind/earthquake moment.
I understand how the shear...
Hi all,
We are currently in the process of ordering a div. II heat exchanger from a vendor. As per table 7.2 of ASME Div. II, some welds require PT/MT inspection. The code however fails to mention if the PT/MT is to be done on either root pass or final pass or both. This is where we are...
Hi all,
I am doing calculations on expansion bellow design to verify a vendor's expansion bellow, I have done almost everything else but, I can't find any way or formula to calculate the lateral, angular and torsional spring rates of expansion bellow. There is a formula written for the axial...
But what is the load path behind them to cause such a stress. Thats what I am pondering about. As far as I understand, 2-2 path is to check for the circumferential stresses (Correct me if I am wrong).
Hi,