UN:
Please could you say how much the carbon steel valve with Stellite overlay cost?
However my preference is to choose the valve I mentioned above.
Rgds Diego
Thanks UNSR,
I thought about getting the following valve:
3" cLASS 1500 gLOBE, rf, bODY: a351 CF8M, Trim: A182 316 SS with Stellite Overlay.
However, I'd assume the worse case scenario that the service is wet Co2. Now are you suggesting the following valve:
A216 WCB, with Stellite overlay...
Thanks Guys,
The service is saturated Co2 and I am wondering if I can use A216 WCB body and 316SS Trim except Seat ring with Stellite overlay over Carbon Steel.
I am aware of the noise but it would not be operated regularly.
Rgds Diego
People,
I want to use a 3" Class 1500 Globe valve on the following service:
80% Co2 - 20% Methane
Design Pressure: 150 Barg
Design temperature: -10C to 120C
Onshore application
If I want to use SS trim and body, the valve would be very expensive; however I know my best bet is to use 316 for...
People,
Do you know if it is a requirement that the distance between the compressor surge connection take off from the discharge line and the discharge check valve to be minimum? If so, what is the standard?
Regards,
Diego
Gents,
Thanks for your feedback.
Please could you tell me where is classified as chloride environment?
My application is an onshore gas plant. What about FPSO projects?
Rgds Diego
Gents,
Well, the vessel is to be installed in a normal atmosphere. Co2 media and ops pressure/ Temperature in the order of 150 Barg and 50 C accordingly.
I don't know the paint spec but I can get back to you tomorrow. However, in such a condition what is the suitable/ minimum Choloride...
All,
I have done a Solar Turbine course and I am wondering if anyone can recommend a good book regarding the compressors and turbines as a study/refreshment book.
Rgds Diego
People,
I want to work out the shell thickness of a vessel as per AS 1210 but I am unable to find a formula for minimum required thickness. Could anyone tell me what is the formula to work this out? Secondly, the process data is as follows:
Design pressure: 150 Barg
Material: Plate A240...
Hi All,
Does anyone know if there is a safety zone when performing pneumatic testing? I couldn't find anything in Asme B31.3.
Any feedback is appreciated.
Rgds,
Brighton
Guys,
Is there anyone who can provide a guideline on frequency of sampling of the corrosion probes at the plant inlet and slug catcher in a sweet natural gas plant?
Thanks