Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by Domainpower

  1. Domainpower

    Decouple the strain gauge measurement into individual modal response

    Hello Greg, First thanks for stepping in. From paper attached in my previous reply i understood, limited strain gauge measurements under actual operating load is all that is required to decompose and evaluate modal responses as function of time (refer page 8 in attachment).This is exactly the...
  2. Domainpower

    Decouple the strain gauge measurement into individual modal response

    Thanks Jason for paper and tips , I will have a closer look at them. Just few more points for clarity I actually don't want to obtain mode shapes what i want to do is to decompose strain measurements into modal response. I was able to find a Paper which exactly is dealing with the kind of...
  3. Domainpower

    Decouple the strain gauge measurement into individual modal response

    Hello Experts , I have a structure with multiple strain gauges attached to it. It is under fluctuating load. We know the response at any point is basically linear combination of scaled mode shapes. Is it possible to accurately decouple the total strain response from each gauge into modal...
  4. Domainpower

    Resonance in Balded Disk

    i would highly appreciate if someone could clear my doubt regarding resonance condition of a cyclic structure (say Bladed disk). Most of the articles mention two conditions to be respected: matching frequency ( excitation force and natural frequency) matching nodal diameter of the structure...
  5. Domainpower

    Resonance condition in Bladed disk (Cyclic structures)

    i would highly appreciate if someone could clear my doubt regarding resonance condition of a cyclic structure (say Bladed disk). Most of the articles mention two criteria to be respected: matching frequency ( excitation force and natural frequency) matching nodal diameter of the structure with...
  6. Domainpower

    Comparing Modal analysis FEA vs Experimental / High modal density problem

    Hi Greg first thanks for the interest.Experimental modal analysis is new area for me. So may be i was not able to provide you with adequate information. By first plot i wanted to show that by FEA modal analysis i get a set of natural frequencies whose values are very close to each other (Case...
  7. Domainpower

    Comparing Modal analysis FEA vs Experimental / High modal density problem

    I have a bladed disk with 21 blades. By FEA i have obtained the First family of in plane bending modes. See the attached file(FEA_results). http://files.engineering.com/getfile.aspx?folder=2720cf01-3b8b-4bfa-bb74-05a88111a23e&file=FEA_result.png After i did an experimental modal analysis using...
  8. Domainpower

    Missing nodal diameter

    Thanks amanuensis for showing interest. May be i did not made my problem clear. I built 1/3rd sector of model and applied cyclic symmetry.Hence results should follow ideally: Harmonic Index Nodal diameter set 0 : 0,3,3,6,6,9,9,12,12...... 1 ...
  9. Domainpower

    Missing nodal diameter

    Is any additional information required GregLocock?
  10. Domainpower

    Missing nodal diameter

    Can someone provide a bit insight into the problem.
  11. Domainpower

    Missing nodal diameter

    Thanks Greg for clarification. I have attached the picture below in word format , i hope this should help. Also is it likely that as i have displacement constraint not symmetrical (that is i don't have them on both sides) , i am missing nodal diameter 1 and 2? Please...
  12. Domainpower

    Missing nodal diameter

    Sorry Greg but i couldn't pickup your hint.
  13. Domainpower

    Missing nodal diameter

    Hi all , I am doing modal analysis of a rotating machine.In my first run i used a sector and applied cyclic symmetry analysis in ansys code. i tried to extract first 10 nodal diameters of bending modes. I was able to identify bending modes for nodal diameter = 0,3,4,5,6,7,8,9,10. However nodal...
  14. Domainpower

    Interpreting Modal analysis results with excitation frequencies

    Dear GregLocock , From the testing team i got the input that maximum variation for nozzle to nozzle excitation can't go beyond 1%. For damping ratio values we have done hammer test on the bucket to get the individual values for each natural frequency. Now i have to use these damping ratio...
  15. Domainpower

    Interpreting Modal analysis results with excitation frequencies

    Thanks Greglocock for your reply,I am new to vibrations and will go with your experience. Now when i take all the modes into consideration, what are the potential points i look into my Campbell diagram (from FEA) in addition to resonance frequencies? In other words i am not sure what impact...