Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by doubleT87

  1. doubleT87

    Pump Suction

    Ok great. Thank you guys for all of your help - I appreciate it!
  2. doubleT87

    Pump Suction

    1gibson- Thanks for your response. I'm trying to keep out primarily rocks. However, I hadn't considered bolts/studs or anything long with a dia. less than 1.25". This is out in a field near a caliche pit and I'm concerned about rocks blowing into and settling in the sump of the pit. I did look...
  3. doubleT87

    Pump Suction

    LittleInch- That's what I was afraid of... this is my first time designing a suction system and we're pulling out of a pit that's relatively deep and I want to ensure that I have plenty of NPSH to avoid tearing up the pump. I didn't think about all of them being in parallel. Thanks for the reply.
  4. doubleT87

    Pump Suction

    Hi, I'm new to Eng-Tips and I'm looking for a bit of advise. I'm trying to calculate head loss in my suction system and I'm having second thoughts about how to calculate this through a small part of a perforated "stinger". I'm perforating a HDPE pipe with 375-1.25" holes (to meet 3x the area...