Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by frank201

  1. frank201

    Pipeline cathodic over protected

    for sacricficial anode it's difficult to measure the E OFF , i think is better to use corrosion coupon to mesure the E off
  2. frank201

    Pipeline cathodic over protected

    each 25 anode are branched together in one test point
  3. frank201

    Pipeline cathodic over protected

    Cu/CuSO4 reference electrode The number Mg anodes is 100 anodes (7kg) spacing approximately 30 metres thanks
  4. frank201

    Pipeline cathodic over protected

    Dear expert . We work in new construction (12 inch) pipeline 3 km with 3LPE coating. The method we are used in cathodic protection is Sacrificial anode. We make 4 Test points . The potential (CSE) is around -1600 mv ( pipe over protected) Please advise if there some risk of coating disbanding...

Part and Inventory Search