Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by GianlucaTempesta

  1. GianlucaTempesta

    Force Required to Open Door

    Thank you so much!!!
  2. GianlucaTempesta

    Force Required to Open Door

    Hello, this door in fitted on a civil construction! Kind Regards
  3. GianlucaTempesta

    Force Required to Open Door

    Weight(kg) 1400 D (mm) 390 D1(mm) 880 Lb(mm) 1270 L(mm) 2500 s(mm) 90 Rv (N) 3433.5 Rh (N) 6867 R (N) 7677.539401 C.attr 0.01 Mattr (Nmm) 174421.8 F (N) 69.76872 teta 95 teta transient 1 stroke actuator 200 vel min 7 t totale 30.57142857 t constant (s) 28.57142857 t transient...
  4. GianlucaTempesta

    Force Required to Open Door

    Hello Ted, thank you so much for your reply. So I have this situation. Weight of door 1400 Kg Dimensions 2500x2500 mm Door is hinged on a vertical side Hinges are working on ball bearings. Opening angle from 0° to 95° t1 = 2 sec t2 = 30 sec teta 1 = 1 deg teta 2 = 94 deg I'm going to open and...
  5. GianlucaTempesta

    Force Required to Open Door

    thread1083-438231 @hydtools I found this formula, F = (I*(95 - theta)*pi)/(180*r*t*(20-t)) Could you explain how did you get it Thank you in advance. Kind Regards