Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!
Green white
Reaction score
0

Member profile Profile posts Latest activity Postings About Post areas

  • Loading…
  • I have a pipeline with a DP of 900 psi that will be Hydrotested to 1125 psi


    in this pipeline there are 6 ball valves to drain/ vent the pipeline. Those valves (rating # 600) and accordingly the max operating pressure for those valves are 1480 psi.

    can I hydrotest the pipeline with valves in closed position, and without installing blind flanges because it is difficult to remove during the hydrotest?
  • Loading…
  • Loading…
  • Loading…
  • Loading…

Part and Inventory Search