Hi mbeychok,
Thank you for all those useful info. However, in my spreadsheet, base on different Gas Handling Capacities, preliminary diameters were calculated for each condition.
Clean Conditions
High Pressure >20 Bar g
Vacuum Operation
Highly Corrosive
all these four conditions above used V =...
Dear all,
This is my first internship this summer, so I am really new in this field.
I am validating a Vertical Vessel Sizing spreadsheet. One of the contidion is Liquid Degassing, the equation used was
Diameter=7608* ((Liquid Flow/3600*Liquid Viscosity)/(Liquid Density-Vapor Density))^0.5...