IRstuff,
Thanks for replying. Yes, i do have basic understanding on the subject.
Referring to this thread,
thread391-69025
Last post:
"Assume the outside temperature is 25oC, wind and radiation effects result in an external htc=15W/(m2*K)"
"There are graphs that help in estimating the...
Ione, Thank you for your reply. I had already read the topic you suggested before I posted this. In fact, I posted this because, to the best of my knowledge, only mention of effect of wind velocity in the above topic is in reply from "boilerone". As per the reply, it seems the change in ambient...
Hello All.
This is my first post in this forum.
Please refer to the attached file. It’s an excel file for calculation which I tried to develop (formulas used are written) and when I substituted the Input values from vendor data it gives correct output (Outside metal shell temperature) as given...