Hi All,
Thank you for all the responses. I'm in Australia, so I apologise that I could not reply in a timely manner.
To add more information, the rate of dosing is approximately 10L/min, so the velocities in the line are extremely low. The dosing is expected to be continuous, as this is dosing...
Hi All,
I am currently designing uPVC Sch80 chemical dosing lines containing Sodium Hypochlorite (0.8%) and am trying to understand how to properly derate the PVC (and find the temperature rise in the pipe) for the following options:
Buried concrete box culvert - nominal depth 450mm