    Here is a simple approximation that you could use as a sanity check. It would err on the conservative side so you may slightly oversize...
  • katmar
    katmar replied to the thread Air valve on falling main.
    1. It appears that your discharge is at a higher elevation than the source, so I cannot see how a siphon can form. 2. The friction...
  • katmar
    katmar replied to the thread Bernouilli in vertical pipes.
    In order to be able to offset the pressure loss in the up-leg against the pressure recovery in the down-leg you have to ensure that the...
  • katmar
    katmar replied to the thread Liquid outlet pressure concept.
    The whole question of entrance and exit pressure losses, resistance coefficients and pressure recovery is generally not well covered in...
  • katmar
    katmar replied to the thread Water siphon question.
    Is it possible to avoid the high point by following the contours from the source to the destination? If you bring the highest point...
  • katmar
    I agree with LittleInch that you have an error in your Bernoulli calculation. Assuming that you are pumping something similar to water...
  • katmar
    katmar replied to the thread Pressure in vacuum line.
    @Javier Sanchez - You can use a similar technique to the way you would match the curves for a centrifugal pump system. The difference is...
  • katmar
    katmar replied to the thread Pressure in vacuum line.
    As pointed out by Pierreick and Snickster, the up and down voting system is a bit confusing if you have not seen it on other forums...
  • katmar
    katmar replied to the thread Pressure in vacuum line.
    @Asisraja D - you have correctly identified the data required for this calculation but you have not got the correct values for that...
  • katmar
    katmar replied to the thread Pressure in vacuum line.
    @Asisraja D - Your general procedure makes sense, but there are a few items I believe you have got wrong. Bottled nitrogen is unlikely...
  • katmar
    katmar replied to the thread Pressure in vacuum line.
    To the member(s) who voted down the posts by me and pierreick - you are absolutely entitled to disagree with any post here, but it adds...
  • katmar
    katmar replied to the thread Pressure in vacuum line.
    For the pressures at which you are working, a well designed piping system will have essentially no pressure drop. All the pressure drop...
  • katmar
    katmar replied to the thread Pipe inlet design.
    Unless there is a dip pipe inside the tank that is connected to the outlet piping the loop on the outlet is not a siphon. It is just a...
  • katmar
    katmar replied to the thread Pipe inlet design.
    I think that LittleInch nailed it, even though auto-copulation added some confusion. The loop will not help with condensate collection...
  • katmar
    What is the design pressure for the main tank? How did you select 7" as the outlet line size from the seal pot? Where does this outlet...