You are right.
Thank you so much
Do you know why A694 group (as i khow) are not exist in part D table 4/5 but exist in B31 3?
Does div2 comeetee have a plan to add them?
The allowable stress in UCI-23 (Su/10) is for cast iron and conservative.
I have been using Coulomb-mohr safety factor for years for above epoxy insulator and the equipment has been working without problems for a long time in gas distribution piping system.
Thank you TGS4
I got it.
But some common used ductile materials such as A694 (for high pressure fittings) are not present in asme.
You mean I can't perform FEA for them according to VIII-2 part5?
Know
If you are agree
Is the maximum stress theory sufficient for the brittle material (max principal stress <Su), or should a more conservative theory coulomb mohr safety factor be used?
Good question.
Generally, I design pipeline equipment which are made of steel. So the code is viii-2. Preparing Elastic-plastic analysis, local failure check, ratcheting check etc.
But in this case i have brittle parts inside the steel parts.
Brittle part is Astm D709 G10 with Su=275 and Sc=414...
The purpose of EP analysis is to evaluate protection against plastic collapse.
What do you think if i assign ep material for that brittle parts and run up to convergence and approving metallic parts.
Then
Check stresses for that brittle material separately in simple elastic analysis with that...
As you can see, green parts are brittle.
Please help me for E-P analysis.
https://files.engineering.com/getfile.aspx?folder=74bf089d-4e77-4bca-b322-e199c37ec3ae&file=IMG_20240622_021004.jpg
Hi,
I have a project which is a part of pipeline equipment (insulation joint) that contains a brittle filler between metallic parts.
How can i perform elastic-plastic analysis?
Is it possible to use perfect plastic for that material?
Sorry would you tell me the reference code?
And
Why we use design loads for elastic ratcheting criteria (PL+Pb+Q) instead of operating loads related to your answer for elastic-plastic analysis?
Hi
Please tell me in order to evaluate elastic-plastic ratcheting in a vessel, which kind of load should be considered, Design pressure or operating pressure?
Thanks
Hi,
Can anyone tell me a procedure to design an Equal Tee?
The client has been asked us to consider proof test according to MSS-SP75 rely on actual ultimate strength. So i performed an Elastic-Plastic FEA according to ASME viii-2 but the Tee will shakedown because of the high proof test...
I mean stress concentrations in discontinuities for example where the hub rings attached to the pipeline.
In elastic analysis for hydrotest, code told that we have not to consider local and secondary stresses but what about E-P analysis ?
Let me review:
A-The design pressure is 2000 psi. For...