Thanks flexibox.
The Stuffing box pressure is 41-45 BAR, we would like to use individual 53B systems for each seal and the seals have individual monitors actually. Due to the high pressure in the seal chamber, Chesterton desing a enginnered solutions for this application, based on high pressure...
Hello Friends
I`m working in project to make a improvement for better result in the sealing system on a Multi Phase Pump twin Screw IDP, handling Gas + Crude Oil, actually we`re using double seal with API Plan 54, with a lot of problem with this plan, it is very complicated, and we need some...