Recent content by Nad87

  1. Nad87

    Bad Odor in raw water

    Hello Dear all, one of our friends have RO plant and raw water is ground water bur there is bad odor coming from the raw water now am thinking that maybe we need to install a degasifier Maybe am gonna visit the site there so what do you think? and what kind of data do you advice me to collect...
  2. Nad87

    ppm of Chemical dosing

    Thank you all
  3. Nad87

    ppm of Chemical dosing

    0707 jari001 Thanks a lot MJCronin thanks anyway but just take it easy bro here it is a forum if any one know a simple information which can help just share with others without too much philosophy it is as simple as that only there is a recommendation for each chemical for example antiscalant...
  4. Nad87

    ppm of Chemical dosing

    Dear all, In water treatment plant there are many chemicals used and as I know there is a concentration of each chemical recommended from the supplier according to raw water analysis. Please anyone can explain me how they recommend the concentration of chemicals or anyone know the relation...
  5. Nad87

    Replace stainless steel 316 pipe

    Thanks all for replying @EdS yes that is true the ss 316 is the best material to treat high pressure and avoid corrosion problem. @Dhurjati yes am trying to find even 304 but still not available because of block of some areas means we don't have many choices because of this pandemic...
  6. Nad87

    Replace stainless steel 316 pipe

    hello, there is too much leakage in our ss pipe we tried to weld many times but not succeed also stain less steel 316 is not available now in the market because of this pandemic that is why am trying to know which type of material we can put in place of stainless steel pipe? we have RO plant to...
  7. Nad87

    PPM and Dosing Pump for chemicals in RO plant

    Dear all, Please is there any specification for concentration of chemicals in ppm for each water (with specific use) means for example we have sewage water we will treat it with RO to product water to use in chiller and cooling tower after and I find this equation ppm= ltr/h* dilution ratio...
  8. Nad87

    Need Help In Technical Report

    Hello, Dears Our RO plant is working for more than 5 years now and we need to check spare parts and replacement for the majority of parts. I searched for these parts and I prepared quotation for. I should prepare now a technical report to convince the client that we need to replace some items...
  9. Nad87

    need Prorated Limited Warranty of Hydranautics ESPA2-LD RO membranes & dizzer® XL 0.9 MB UF modu

    Hello, I'm searching for Prorated Limited Warranty of Hydranautics ESPA2-LD RO membranes & dizzer® XL 0.9 MB UF modules. I have one example here but for other mark https://res.cloudinary.com/engineering-com/image/upload/v1586351924/tips/Three-Year_Prorated_Limited_Warranty_z5aurk.pdf
  10. Nad87

    Stainless steel pipe RO leaking

    @LittleInch 17 bar
  11. Nad87

    Stainless steel pipe RO leaking

    Dear all, Thanks for replying For who told me about new material, yes you have reason and that what i suggested but now it's very difficult to find material the majority of workshops and shops are closed and some industrial areas are closed also so that is why we are trying to fix without...
  12. Nad87

    Stainless steel pipe RO leaking

    Thanks a lot for replying, I already give it back to the workshop and I asked them to remove all the old welding and corrosion and make grinding then we can weld again. we will see maybe if they clean it good it will work the argon welding is stronger one. Thank you all
  13. Nad87

    Stainless steel pipe RO leaking

    thanks for replying, here is photos
  14. Nad87

    Stainless steel pipe RO leaking

    Hello, there is on ss pipe in small RO plant which was not working maybe for 1 or 2 years now we are checking to restart this plant the proble in the ss pipe there is leakage in elbow and T our workers tried to fix with normal stainless steel welding rod 2 times but still leak coming also we...
  15. Nad87

    Dosing Pump and Concentration of Chemicals

    Dear all, thanks a lot for replying I found one equation saying ppm = dosing pump flow*specific gravity*dilution*1000/feed flow. I think for dilution the mean how many liters of chemical we should put and mix with water in the tank. Really this is the first time I see this equation and am...

Part and Inventory Search