Thanks
It helps. But now when I select the part and press ESC part starts deselecting very slowly. Should I re-install ug?
It just became unacceptable slow.
NX 9: whenever my cursor comes over any part in 3D- modeling, the part starts highlighting itself, line by line, and I have to wait that it is over to continue working. I just must not touch any part with cursor.
How to fix it?
Thanks
Blas
Thanks a lot for win10 info. I am forced to use it (at this moment) because my win7 has no driver for sky-lake cpu-usb3. All I use windows for, beside operating system, is win-explorer to copy/paste/erase files, so I am actually not interested in its capabilities.
NX10: I use NX7.5 to model...
I can run NX7.5 on win10, but some parts (commands) of menu are just not there (compared to win7) (e.g. Analysis > measure surface) and it has to be run through command finder which gives an option to include it into the menu. But after the reset it is the same.
I just wonder if it is the same...
Can someone comment on difference between FEMAP (latest) and ug-NX7.5, regarding FEA, with single part and assembly
Linear
non-linear
fluid flow
thermal
size of the model (eg. FEAMAP can handle whole construction machine assembly, NX only "small" assemblies)
File > export > stp
when selecting parts to be exported do not click at individual parts but select them all at once with rectangular system : point the cursor at upper Left corner and then drag the cursor across whole assembly.
I have Nx7.5, 16 GB memory (RAM), DeLL work station, SSD
in NXNSTRAN > BIN >..
there are
LP solvers, which can address max 8 GB RAM, and it works fine
Nastran.exe
nastran64.exe
ILP solvers, which can address max 1 TB of RAM, and I can't make them works with more than 8 GB
nastranw.exe...
The answer is in verifying your FEM. It is a good question how you know your result is not 200% off.
Remember: any FEM MUST be verified, otherwise it is useless to anyone.
Remember: FEM result is only 3% job done, rest 97 % is still engineering work...
However, nowadays looks that 97% of the job...
I have Nx7.5, 16 GB memory (RAM), DeLL work station, SSD
in NXNSTRAN > BIN >..
there are
LP solvers, which can address max 8 GB RAM, and it works fine
Nastran.exe
nastran64.exe
ILP solvers, which can address max 1 TB of RAM, and I can't make them works
nastranw.exe
nastranw64.exe
I made...
NX 7.5 and Win-10, high resolution screen
To max graphic area, I move icon by icon into graphic area and then click at X to remove the icon set which i do not need. It were all fine with Win-7. However with Win-10 , whenever I pick the icon-set (e.g standard) and try to move it into graphic...