  1. Paciallas

    Two pumps connection

    Thank you for response. Best Regards
  2. Paciallas

    Two pumps connection

    Thanks. Of course there should be considered additional PIA and shutdown protection, etc... I have attached only a simple idea, i left the rest to the designer. If I show him that such arrangement is used somewhere, it should be the strong argument to convince the designer. So please, can...
  3. Paciallas

    Two pumps connection

    LittleInch, thank you for response. In my opinion, the flow controller should be in the discharge pipe of the new one pump and I will suggest this to the designer. It should be enough to avoid any problems with the whole system. "The rest" of diesel oil is directed to the surge drum so I think...
  4. Paciallas

    Two pumps connection

    Hi to ALL. I would like to ask what do you think about connection of two pump, where suction line of pump 1 is rooted directly from discharge of pump 2 (process medium flow through air cooler and then part of it is rooted to pump 1)? What disturbances could occur in such configuration? Process...