Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by purduemateng

  1. purduemateng

    T22 Initial Heat Treatment Cooling Rate per Industry Standard

    Hi, I'm working on an atlas of microstructures for T22... I know pretty basic stuff, but I'm having an issue mimicking an industrial heat treatment in our little box furnace here at the lab. Ultimately, I'm performing an isothermal anneal and a normalize/temper heat treatment. The goal is to...
  2. purduemateng

    T23 T11 DMW Failure

    one more!http://files.engineering.com/getfile.aspx?folder=c80f9293-db74-4e46-85b9-8a82c02bbf70&file=Crack_at_Wall_Mid_etched_50x-2.jpg
  3. purduemateng

    T23 T11 DMW Failure

    additional micrograph...http://files.engineering.com/getfile.aspx?folder=4c2d9e14-06a3-4d90-b6ba-cd8bd965e98c&file=Crack_at_Wall_OD_etched_50x.jpg
  4. purduemateng

    T23 T11 DMW Failure

    I'm new to this site, so hopefully I'm posting in the correct area. I have an issue with a failed tube that we received in our lab. It is a T23 to T11 DMW with an 80S-B2 filler metal. At the moment I can say that, in the two sections we’ve examined, that the crack is filled with oxide and...