Thanks. Thats what I was suspecting too. Unfortunately dont have 2019 resistivity values.
Hence, I am conducting CIPS on the lines now. Would that be enough to give me more confidence as to the condition of the coating?
Hello everyone,
I am conducting a DCVG survey on our plant's gas lines. The coating is very old (~30 years), and has been rarely inspected. In the last DCVG survey in 2019, a moderate severity fault was detected at a location with %IR of ~16%. This time around, at that exact same location, only...