Hi EireChch,
Thank you for your message. We currently do not have any results from CU tests.
Two of the UU test results, which include plots of deviatoric stress against strain and shear stress against strain, are attached in the following Excel file.
Hello everyone,
I recently reviewed the test results from the Unconsolidated Undrained Triaxial Test. In theory, the undrained shear strength (Su) should be consistent across different cell confining pressures. However, my test results indicate that, as the confining pressure increases from 200...