Thanks KevinNZ.
in your snapshot, the displacement in y-direction is 450mm, even though the expansion length is only 70 m on one side and 20 m on other side. Can you check why we are encountering this high displacement? The displacement should not be more than 100mm considering CS pipe...
Its a 3Km long surface laid flowline.
X at each end represents crossings which can be considered as anchor point as buried depth is approx 3 m
the lateral deflection is at the bend in horizontal direction.
pipe is SCH 120.
Expansion coefficient is calculated by Caesar software, we just have to...
I am performing stress analysis of above ground surface laid flowline with buried portion only at crossings (road, existing facilities etc.). the MOC is API 5L Gr-B and the design code we are using is ASME B31.8. In one of the section of the flowline, we are having an IP (change in direction)...