Vrpeng-tips's latest activity

  • Vrpeng-tips
    Vrpeng-tips replied to the thread U2-(g), appendix 46.
    Any feedback would be appreciated. Thank you in advance.
  • Vrpeng-tips
    Vrpeng-tips replied to the thread U2-(g), appendix 46.
    OK. did some more reading and I think I have little more clarity. So, FEA can be used under U-2(g)(1)(-c) to design component thickness...
  • Vrpeng-tips
    Vrpeng-tips replied to the thread U2-(g), appendix 46.
    I say the method is not valid because Div.2 part 5 is not being used. 1. Not checking all modes of failure. 2. The stress limits are not...
  • Vrpeng-tips
    Vrpeng-tips replied to the thread U2-(g), appendix 46.
    Thank you IdanPV and TGS4. thank you for pointing out UHX-1(7)(b), my bad I didn’t read that far. So I am left with, Option one =...
  • Vrpeng-tips
    Vrpeng-tips replied to the thread U2-(g), appendix 46.
    IdanPV, I really appreciate your reply. It actually made me RE-READ the code. I also read your other post...
    • 1742074125744.png
    • 1742074161228.png
    • 1742074188690.png
    • 1742074421909.png
  • Vrpeng-tips
    Vrpeng-tips replied to the thread U2-(g), appendix 46.
    Not sure if I am being clear or not. Let me rephrase my questions & background. fixed tubesheet heat exchanger, config. b, tubesheets...
  • Vrpeng-tips
    Vrpeng-tips replied to the thread U2-(g), appendix 46.
    Hi IdanPV, Thank you for your response. Yes, the rules for HX have moved to div.2 part 4. Which is design by rule method and shall be...
  • Vrpeng-tips
    Vrpeng-tips replied to the thread U2-(g), appendix 46.
    Hi TGS4, Thank you for your response. For Div.1 ed.2023 fixed tubesheet heat exchanger, all components are designed using Div.1...
  • Vrpeng-tips
    Vrpeng-tips replied to the thread U2-(g), appendix 46.
    Hello Experts, Any insight on this would be greatly appreciated. Thank you.
  • Vrpeng-tips
    Vrpeng-tips replied to the thread U2-(g), appendix 46.
    correction. For a fixed tube sheet div.2 part 4.18 applies. And design can be completed using DBR.
  • Vrpeng-tips
    Hello, Unit - Div.1 U-Stamp heat exchanger Most of the design of the unit can be done using div.1 rules (Shell, Nozzles, head,etc..)...