  1. jor1492

    ECR vs ELR

    Thanks all, very helpful your answers.
  2. jor1492

    ECR vs ELR

    Hi, This is a little out of My area, but I have the question what are the difference between an earth continuity relay vs an earth leakage relay? At the end both of them look for an earth fault ? And in what application one is better than the other ? Thanks in advance
  3. jor1492

    dead head associted with low current?

    Good day everyone, Yesterday I was a issue with one pump operated by motor, where it wasnt deliver enougth flow rate and it was running with low current. at the end I discovered that the problem was a dead head operation So my question is, a symptom of a pump working in dead head is low...
  4. jor1492

    Static Head in Circuit

    thanks gentlemen
  5. jor1492

    Static Head in Circuit

    What is the static head in a system were discharge vessel is not at the highest point in the circuit? Highest point in the circuit is at 11 m from pump discharge. Discharge vessel is at 0 m from pump discharge...
  6. jor1492

    problem with installation of shell plates

    thanks for the answers. I will do the welding in the large gap with the owner authorization. Thanks again.
  7. jor1492

    Weld a support plate over the horizontal and vertical welding lines a tank.

    Thanks IFRs, the tank is ASTM A36. Do you know if API 650 has information about this? thanks
  8. jor1492

    Weld a support plate over the horizontal and vertical welding lines a tank.

    Hello all, I want to know if it is common to weld support pads on the tank shell , if the welding lines are over the welding lines of the tank. if it is not possible what is the reason? see attached picture...
  9. jor1492

    problem with installation of shell plates

    thanks mk3223. Exactly was a vendor error. I am in charge to approve the design deviation.
  10. jor1492

    problem with installation of shell plates

    Hello all, I am working in the erection of the 4 courses of a API tank. In the second course I found that one shell plate is shorter as per design drawings. this generates a bigger gap for the welding ( 2mm in the bottom of the plate and 12mm in the top) see attached sketch. What could be a...
  11. jor1492

    some masters or post graduate degrees to be more successful in the EPC projects

    Hi all, I am a mechanical engineer trying to improve in my career. I want to know what kind of engineering master you could recommend me if I want to specialize in the EPIC projects. thanks in advance
  12. jor1492

    Hydrant, dry barrel modification

    Hello all, I am installing hydrants of dry barrel, but these was bad specified about the barrell length. So to suit we are thinking in modify the barrel (cut to be shorter) and valve stem. From a construction point of view is very easy the modification. But now I am thinking that maybe there is...
  13. jor1492

    specifying J anchorage bars grade 8.8

    as the spec sheet by the vendor is in french I could not notice about this information. After a translation the material spec is XC48 (French spec), this is SAE 1045(American spec) and to achieve the grade, the bolts require to be tempered and quenched. Thanks all by your answers.
  14. jor1492

    specifying J anchorage bars grade 8.8

    Hi all, I want to sent to fabricate J anchorage bars for a tower crane foundation. As per the vendor of the crane the anchorage bars need to be grade 8.8, so my question is: to specify the material for the manufacture, it is enough information for the manufacturer, only specifing him " Carbon...
  15. jor1492

    Avoiding deflection in a rail when the bridge is already installed with a permissible deflection

    Hi all, Currently I have a Gantry (Bridge) already installed with a permissible deflections by the settlement of the structure . Above this structure I will install a shuttle conveyor, Therefore the rail of this machine will present unacceptable deflections that I will require to correct, in...
  16. jor1492

    Diesel pump place without sprinklers

    Hi all. I am aware about the rule, that if I have a diesel pump, I will need to install sprinklers above the storage fuel area as per NFPA 20. This is a common practice. But in the particular project that I am working ( A copper process plant in a copper mine) we have the fire pumps at outdoor...
  17. jor1492

    Re use pipe materials from new pre manufactured spool.

    Thanks by all the answers, At the end, We discovered that the lined is actually polyurethane and this material is unavailable locally. Regards
  18. jor1492

    Re use pipe materials from new pre manufactured spool.

    Hi all, Normally We pre manufactured all our rubber lined spools with a supplier, but now is necessary the modification of one in field. Here we have all the tools and good personal to work in that. In this special case, I am requiring to trim a 1 meter nipple from one spool and this same...
  19. jor1492

    air conditioner unit branch circuit rules

    Hi all, For the design of a temporary camp, small rooms, it has been decided to power each room with a single circuit - 2 pole breaker for an 1100VA Air conditioner split (240V, 2 hot wires 120V each) and from there, one hot 120V phase will continue to power 3 outlets for small appliances and 2...
  20. jor1492

    heat treatment after bending pipes

    HEllo all, I want to know if you recommend to use some kind of heat treatment after the process of bending a pipe. For the bending I am using heat to put more ductile the material. The material is Carbon Steel (api 5l). thanks in advance.