Thanks for all the replies and sorry for the delay.
The slope is indeed constant in the main header and on the branches. We try to keep at least the minimum as per API (2.3° iirc) + the ship pitch/roll values.
And about the measuring, mostly I'm trying to look at the worst case scenario to...
Hello.
I work with drive-pump trains that usually have API 614 lube oil systems (LOS) installed. Those LOS always have an oil return pipeline that works only with gravity, and this return line have quite a few temperature gauges + thermowells to check how hot the oil is leaving each equipment...
Thanks TugboatEng, this solution from Flextallic seems great.
From what I understand, graphite in seawater would create a extremely favorable environment from corrosion.
So in a situation in where the flange material is correctly selected, a PTFE filler gasket would be acceptable, no?
I'm currently working on a seawater piping service and I need to selected the proper gaskets to avoid corrosion due to seawater in contact with super duplex steel.
For seawater, I was told that the "rule of thumb" was to always use PTFE as a filler for spiral wound gaskets, since graphite...
Thansk for your answer! The requirement from 6.4.2.1 actually slipped from us (will make sure to include that), but my original post was more about the actual definition of "machined and studded connections" for pump casings, since it's not our bread and butter configuration.
Hello!
Our engineering team is developing a "API 610 guide for beginners", in which we're trying to make it even easier for someone new to this area to understand the standard's requirements.
One point that got us confused were items 6.4.2.1 and 6.4.3.6 (from API 610 12th ed), which says about...
Hello,
I'm designing a lube oil reservoir as per API 614 guidelines, but one characteristic is puzzling me. In API 614, 1.3.6.2.6 says that "[...] free surface of oil in the reservoir shall be a minimum of 60 cm² for each liter per minute of normal flow".
I tried checking another literature...
Hello, I'm looking for a accelerometer model which has 4-20 mA + HART output, suitable for Zone 1 and 2, but with INMETRO certification (legal reasons).
I tried looking in Bently Nevada's, Emerson/PCB's catalogues and some general Google search, but it seems I'm out of luck, hardly any of them...
For other points, such as low pressure, in which the flow would be high, is it still advised to use trip using the flow? Or in that case pressure tripping is acceptable?
Anyway, thank you very much, I got the answer for my main problem, the rest is just me trying to get better at my job haha
So flow would solve it, I see.
And sorry, I cannot post the pump's curve due to our company's policy, but this thread could be about a general doubt, since we do this process quite a lot, it's always good to know better ways to set our sensors.
So to close this matter, to measure pressure at...
Hi,
I'm working in the instrumentation department, and we need to set the alarm and trip point of a centrifugal pump. I'm having trouble with the high pressure trip value.
According to our pump's curve, the highest discharge pressure would be at shut-off head (348 m) with +5% of tolerance...