Thanks much LittleInch,
Right, so the total system volume is 4.1 M3. Temp is controlled. Inside the isolator is a material feeder (far right) followed by in line air classifier followed by cyclone. Cyclone air discharge goes to filter. The blower draws a vacuum on the system and returns the...
Sorry,
Here is the system sketch.
Mikehttp://files.engineering.com/getfile.aspx?folder=ab5a8c56-2155-4506-a9ec-e07d973e81d2&file=Closed_Loop_System.jpg
I'll try to explain further. I attached a rough sketch and blower curve.
The expectation would be for the blower to operate at roughly 1000 - 1200 mm WG. Actual data taken from Clean duct between filter and blower is 2700-2900 mm WG, 250 M3/HR, motor draw 10 amps.
In my tangle with another...
Looking for assistance with closed loop inert gas process system blower requirements. In an open system discharging to atmosphere the calculated system pressure drop (PD) would be "X". Now,
same system in a closed loop arrangement returning the process gas to the system inlet, we have an actual...
Looking for assistance with closed loop inert gas process system blower requirements. In an open system discharging to atmosphere the calculated system pressure drop (PD) would be "X". Now,
same system in a closed loop arrangement returning the process gas to the system inlet, we have an actual...
Looking for assistance with closed loop inert gas process system blower requirements. In an open system discharging to atmosphere the calculated system pressure drop (PD) would be "X". Now,
same system in a closed loop arrangement returning the process gas to the system inlet, we have an...