  1. minhaj17

    Carbon steel wall thickness as per API 650

    Dear Mohammed, The Operating condition (product design stress) which you have considered is 160MPa, whereas the Client has specified product design stress bottom course=184MPa, upper course=196MPa. Based on the Client's data I guess my calculations are correct. Please confirm if you can. Regards
  2. minhaj17

    Carbon steel wall thickness as per API 650

    Thank You Mohammed.
  3. minhaj17

    Carbon steel wall thickness as per API 650

    Dear All, Thanx for your replies. Dear MJ Cronin, As per the data; product design stress bottom course=184MPa, upper course=196MPa Minimum yield strength=250MPa Minimum tensile strength=400MPa Minimum hydro static stress=171MPa, product - water, my calculation shows as, including corrosion...
  4. minhaj17

    Carbon steel wall thickness as per API 650

    Dear All, We are working on a project where there is are requirements to carry out preliminary design. I need some suggestion regarding wall thickness. As per the API 650, 5.6.1.1, the minimum plate thickness required for 36m diameter tank is 8mm. Now my question is does this 8mm includes...