  1. Fayaz810

    Plumbing Code Issue

    Hello, I never faced this situation and I need your advice ............ I am working on a project in Saudi Arabia. The design shows about 20-Toilets in a row sitting on a 7-ft slab. These are eastern toilets (Squat Type) with no integral P-trap. P-traps have to be installed for each...
  2. Fayaz810

    Plumbing Code P-Trap

    Hello friends, I never faced this situation and I need your advice ............ I am working on a project in Saudi Arabia. The design shows about 20-Toilets in a row sitting on a 7-ft slab. These are eastern toilets (Squat Type) with no integral P-trap. P-traps have to be installed for each...
  3. Fayaz810

    Mechanical Room

    sorry, I forgot to mention,,,,,,,,,,,, We are using International Mechanical Code (IMC)
  4. Fayaz810

    Mechanical Room

    Hello experts, I am working on a project where ................ Two air-handling units located in one mechanical room serve two separate fire-zone. Return air is ducted. Mechanical room has tight space. If I delete return-air ductwork inside mechanical room and make it as common plenum with...
  5. Fayaz810

    Booster Pump Schematic

    Dear Friends, I uploaded the file again. Please look at the schematic Regards Fayazhttp://files.engineering.com/getfile.aspx?folder=0ba75c1b-4b9a-45f0-91d4-7ef581b1aec5&file=PUMP_HOUSE_x-Model.pdf
  6. Fayaz810

    Booster Pump Schematic

    Dear Friends, Please see attached drawing I am designing a job for an oil field where a water booster pump set will be installed. It is a labor camp of 200 people with an elevated tank in a desert. I have done loop and pressure calculations. I just want to make sure, if my booster pump schematic...
  7. Fayaz810

    Grooved Pipe

    I never worked on Grooved Piping before but now I have to do shop drawings for a project. The question is ............ Can grooved fittings be attached to each (directly) without using a spool piece? For example ....... I have a shut-off valve + Tee + Elbow, can I connect the valve with tee and...
  8. Fayaz810

    EPANET 2 Emitter Coefficient

    Hello folks, I just started using EPANET. So far I am doing OK but emitter coefficient is confusing the hell out of me when I simulate fire-hydrant loop. I have a fire-flow of 3000-gpm from two farthest hydrants in a loop. I what I enter any large value, the whole loop goes at very low...
  9. Fayaz810

    Fire Hydrant Loop

    Dear friends, I am required to design a simple fire hydrant loop for a private development (hotel / mixed use building). No of Hydrant 6 Size of loop = 8" Flow = 1000 gpm each hydrant Two farthest hydrants could operate at the same time Pump will pick water from a storage tank (no city water...