Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. cfuller

    Liquid CO2

    What are you trying to do? Cool rubber on a mandrel Get to liquid at a certain pressure? No set process pressure but need to be discharging liquid CO2 for the rubber Use the CO2 for cooling? Yes Or can you increase the pressure? No, it's a set pressure at the tank How is pressure being...
  2. cfuller

    Liquid CO2

    Thanks everyone for responses. I don't think this is a problem that can be solved through a forum. As I said in my original post, is there a consultant or applications engineer who could help?
  3. cfuller

    Liquid CO2

    Thanks for the response. The system has 1-1/2" piping with 1-1/2" insulation and the loop is 700' so the supply/return are 350 ft each. We're using a Blackmer CRL 1.5 (Sliding Vane) pump. The pressure at discharge is 285 psi and 20 F.
  4. cfuller

    Liquid CO2

    I've installed a liquid CO2 system but keeping getting gas CO2 at the discharge rather than liquid. I've tried various things such as bringing the supply/return closer to the machine and increasing the line size but for some reason I can not get the system cold enough to get liquid. It's...
  5. cfuller

    IEC vs NEMA Contactors

    I'm writing a bunch of specifications for new equipment especially new bridge cranes. I've been told two different stories regarding using NEMA contactors vs IEC contactors. I've been told that NEMA contactors are superior and heavier duty but then have been told NEMA contactors are costly and...
  6. cfuller

    Pit Fill

    I've got to fill in a 15' W x 15' L x 33' Deep concrete pit then pour an 8" slab for a machine. I'm a mechanical engineer this subject really isn't my wheel house. It's been suggested to fill in gravel and compact every 4'. My question is that typical way filling a pit? If so how do safely...
  7. cfuller

    Safety Permit Question

    We have had a few issues where contractors will either sawcut, jackhammer or core drill through conduits or water lines at our plant. We've got permit called a penetration permit but it's still not preventing the issue. I'm sure we not the only plant with this situation. What do others do to...
  8. cfuller

    Cooling Tower Coils

    Thanks we are. BAC is have metallurgist look at them as well as our metallurgists.
  9. cfuller

    Cooling Tower Coils

    Good question. We have asked BAC. They said they manufacture the tubes here in the US.
  10. cfuller

    Cooling Tower Coils

    Yes, the manufacturer has been contacted. These can be replaced on warrantee however this will be third set of coils on these cooling towers to be replaced. Every time it's a failure along the weld on the tube.
  11. cfuller

    Cooling Tower Coils

    These are cooling towers. It's a closed circuit Baltimore Aircoil. To replace the tube, the entire coil would need to be replaced because it's a serpentine style coil and the leaks are in the tubes buried in the coil. Can coils be purchased with seamless tubes?
  12. cfuller

    Cooling Tower Coils

    We have 3 cooling towers with the coils leaking. One tower has been installed for 6 months and the other two have been in for 18 months. These appear to be leaking from the weld along the seam of the tubing. Has anyone experienced this before? If so what did you to fix it? Can coils be...
  13. cfuller

    "R' Stamp Question

    Thanks for the reply. Do you have an idea on costs?
  14. cfuller

    "R' Stamp Question

    Our company is looking at getting an "R" stamp for repairing our own pressure vessels. What are the necessary steps and is this a costly endeavor? Can we have a company employee be the Authorize Inspector or are we required to a have third party inspector? Thanks