Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. cjgrass

    Welder qualification to API 1104 20th edition

    Thank you for the reply. This is an ASME IX requirement i was wondering if API 1104 had anything similar.
  2. cjgrass

    Welder qualification to API 1104 20th edition

    Hello, If a welder takes a qualification test and passes for company A finishes the job and does not come back to work again for company A for 18 months. Does he need to re-qualify for company A? If so where does it say so in the code? Thank you for your help
  3. cjgrass

    AWS D1.1 pre qualified wps

    Thank you both.
  4. cjgrass

    AWS D1.1 pre qualified wps

    My question to the experts is this- When preparing a prequalified wps for FCAW-G using E71T-9/0.045" wire and 75/25 shielding gas is it allowable for example to list amperage as 150 - 180 +/- 10% and voltage as 22.0 - 28.0 +/- 15% and travel speed as 4.0 - 10.0 ipm +/- 25%, provided these values...
  5. cjgrass

    Welding A333Gr6 to 4130

    Thank you sirs.
  6. cjgrass

    Welding A333Gr6 to 4130

    Thank you for your responses. The thickness of material is 0.625" 3.5"OD pipe. The MTR states ASTM A519, HOT ROLL-QUENCH-TEMPER. Service is low-temp impacts @-50 required.
  7. cjgrass

    Welding A333Gr6 to 4130

    We need to develop a wps to weld A333 grade 6 to 4130 to ASME XI. Could you help with recommendations for filler metal GTAW root and hot pass and SMAW fill/cap and pre heat. i don't see anything in the welding spec's that calls out PWHT? The material size is 4 inch sch 160. Thanks in advance.
  8. cjgrass

    Porosity versus gas pocket API 1104 20th edition

    When interpreting radiographs to API 1104 20th edition para. 9.3.9 calls out porosity, figures 19 & 20 use the term gas pockets. Should the reader sheet/interpretation sheet indicate porosity or gas pocket for an individual pore, seams trivial to me but we are getting flack from QA for using gas...
  9. cjgrass

    welding L-80 casing to 4130

    Thanks a bunch for your time and expertise. what would you consider the maximum acceptable hardness range to be for these materials? we will be using Vickers HV10.
  10. cjgrass

    welding L-80 casing to 4130

    We are considering GTAW root & hot pass SMAW fill and cap, ER80S/E8018B2L or C3. the 4130 is N Q&T. The MTR for the L80 shows 0.30% C, tempering temperature of 1150F. thank you
  11. cjgrass

    welding L-80 casing to 4130

    We need to develop a welding procedure for welding L-80 Type 1 casing to cone shaped for lack of a better term "end caps" of 4130 material. the pipe and cones are 13.375" x 0.375". my greatest concern is the PWHT that would be required after welding. design temperature is -50F to +250F. design...
  12. cjgrass

    Lincoln LH-D

    As have I chicopee (37 years) and being in the test lab bushiness I have my reasons for the skepticism, i was more interested in if anyone out there has any experience with this electrode. Thanks again.
  13. cjgrass

    Lincoln LH-D

    Hello- There is push to switch from using cellulose (E8010-P1) downhill electrodes for pipe welding on the North Slope of Alaska by one of the owner companies to using low hydrogen electrodes. I understand that Lincoln has what they call a downhill low hydrogen rod LH-D that they claim can be...
  14. cjgrass

    PWHT hardness

    Thank you.
  15. cjgrass

    PWHT hardness

    Hello all, We have some P5B pipe 6" sch 40 material that needs to be PWHT to ASME VIII Div. 1. My question is there a requirement to do hardness testing on the material after PWHT? Thanks
  16. cjgrass

    AWS D1.1 new Clause 9

    Thank you, sorry for not being more specific, i was talking about wps qualification to table 9.10.
  17. cjgrass

    AWS D1.1 new Clause 9

    Al- I have a follow up question to this- in the past in order to qualify CJP API 5L X65 pipe to ASTM A572Gr50 plate for pile caps for example we would roll 1/2" A572 plate to match 8 5/8"ODx0.500"X65 pipe. So if pipe no longer qualifies plate how would you qualify a scenario such as this? Even...
  18. cjgrass

    Tubular Connection

    When a pipe pile is welded to a pile cap with a CJP weld with backing, is this considered a Tubular Connection? If so do the welders performing these welds need to be qualified on pipe if the pile pipe is less than 24"OD? Thanks
  19. cjgrass

    AWS D1.5 CVN testing

    Hello, I have a question concerning cvn testing to AWS D1.5. When calculating the average ft/lb for the 5 weld metal cvn samples are the high/low values excluded or are all five specimens averaged? Thank you.
  20. cjgrass

    API 1104 20th edition welder qualification

    My question is is it allowable to test two welders on one coupon, one would weld one side and one would weld the other side of the test coupon, if the test assembly is inclined 45 degrees to qualify all positions for each welder? The test would be on 18"OD x 0.500"WT X65 line pipe radiography...