Tommy HS (Petroleum)(OP)15 Oct 20 09:06
Hi all,
I would like to get opinions about D/P transmitter(Emerson 2051 Series) installation for Dry Gas Measurement.
As you know already, all of vendor generally recommend to install the transmitter above dry gas service pipeline.
But now, the...
Hi all,
I would like to get opinions about D/P transmitter(Emerson 2051 Series) installation for Dry Gas Measurement.
As you know already, all of vendor generally recommend to install the transmitter above dry gas service pipeline.
But now, the pipeline with flow element(venturi) is at...
Thanks for all your replies.
I get to know that the gas entrapped doesn't give any impact to reading and I agree with the side tap orientation tends to make obstruction in the pipe rack.
However, unlike your replies, API RP 551 and PIP which are international standards, as well as most of the...
Hi,
I would like to get opinions about pressure transmitter installation location in liquid service.
When measuring liquid pressure in pipeline, the pressure transmitter generally is installed below pipeline with a side pressure tap on pipeline.
This purpose is to vent freely entrapped...