Thanks for prompt reply! This helps a lot.
My problem is that there is already strata present around explosive.
If i take the whole of eulerian domain encompassing all the strata (option 1 in attachment), then EVF value for air (outside explosive) would be incorrect as Langrangian strata and...
Hello everyone. I am using Abaqus software for simulating blast (in a drillhole) by using Coupled Eulerian Langrangian analysis.
I have doubt regarding extent of eulerian domain.
1.) Should my eulerian domain (consisting of explosive only) be limited to volume inside the hole or should it cover...