Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Saedhalteh

    Dowel bars in foundation

    Hello all, I have question regarding Dowel bars and Development length that I hope you can help me with : If the bearing capacity of the concrete is not sufficient to transfer loads from column to foundation then we need to put dowel bars. My question is, does placing dowel bars means that...
  2. Saedhalteh

    Seismic Provisions

    Hello all, what is Seismic Provisions, Is it a complementary code for ASCE that we should follow whenever we are designing structures for seismic loads or Is it only need to be followed in some certain cases ? Would really appreciate if someone could guide me about the Seismic provisions...
  3. Saedhalteh

    Live LOad Reduction ( Tributary area and Influence ARea )

    Hello All, I have read that to determine the "Tributary area" for a Column by Taking the half-area each way, aka "simple tributary area", will always underestimate the reactions to interior columns. and using the unit load approach will give more accurate results for determining the Tributary...
  4. Saedhalteh

    HOWE ROOF and Truss Specification

    thank you dear seth.
  5. Saedhalteh

    HOWE ROOF and Truss Specification

    Hello all! I am confused a little about the naming of the members for Howe Roof structure and would appreciate if someone confirm the below naming convention it it is right or not ? Additionally, when we assign the truss specification for such strucure do we assign it ti the whole view or...
  6. Saedhalteh

    Effective length factor

    Thank you very much, this was very helpful.
  7. Saedhalteh

    Effective length factor

    hello all, When running a P_delta analysis in STAAD, I need to specify the Effective length factor K for the columns, My question Is if I assigned a value of K=1 to all columns will that be conservative or it is a wrong behavior and I need to calculate K for each column and assign a suitable...
  8. Saedhalteh

    voided slabs design software

    Hello all ! Can we use RAM Concept to design Voided slabs ? If yes, could you please suggest a workflow for that ? If No , could you please name a software that can if you know
  9. Saedhalteh

    solar tracking system Structural design

    Hello All, Can someone help me understand the effect of a moving system on the structural design. For example: when designing a Tracking solar system as shown in the link below, will this movement affect the beam design and add additional load to be considered ...
  10. Saedhalteh

    challenges during the Structural information modeling process

    Hello all what are the most common challenges that face the structural engineers in general during the proccess of Builiding Information Modeling and Structural Information Modeling. I am trying to do a resaerch about the common challenges and I hope some of you can help me with especially...
  11. Saedhalteh

    out of plane transverse loads section in code

    hello all Can someone help me find this chapter in AISC 360 -16 code my version nnumbering is shown as 16.1-145 the section that I want to check is the out of plane transverse loads which is indicated in 9-16 page . ( I can't find this page because my numbering differs from it )
  12. Saedhalteh

    Connection design RAM Connection

    Thanks alot for your help .
  13. Saedhalteh

    Connection design RAM Connection

    I am new to the filed so if you could suggest me good source to understand the connection design I would really appreciate it Does the code specify a method to design each type of connection such as Standard tee connection or single plate connection and what forces is applicable to each...
  14. Saedhalteh

    Connection design RAM Connection

    Thank you for replying. I am using Standard tee connection bolted as show in the picture, but when I apply some axial load to the joint it show no capacity check and the ratio is 0.0
  15. Saedhalteh

    Wind load calculation for mounting systems

    from which section we should calculate the wind force from for mounting structure as shown below : do we consider this system as ( Building structure/Chimney,Tank,similar strucures / solid signs/ open signs / Lattice framework /Trussed tower )
  16. Saedhalteh

    Connection design RAM Connection

    Hello all In RAM CONNECTION there are a number of connections and each connection have specified the loads required to formulate all the design checks as shown below now for example a standard TEE Section only designed for shear forces as it shown in the image , my question is this is...
  17. Saedhalteh

    Dynamic analysis

    Hello All Can someone suggest me a good sourcr to understand the dynamic analysis concept (modes,frequency,mass participation , responce spectrum, time history...etc ) Youtube videos , articles ,books iwould really appreciate any suggestion
  18. Saedhalteh

    telecommunication towers on top of a Roof

    If we want to design a telecommunication tower on the top of an old building's Roof what will be the procedure or main steps for that ? how can we verify that the slab of the roof can stand or support the tower sufficiently (because when the building was designed there was no consideration...
  19. Saedhalteh

    TEnsion only member and selenderness ratio

    Thank you all, Really appreciated, It seems that the member was failing due to the suggested value L/R exceeds 300 in STAAD and it turned to be that I can turn this check off in STAAD.
  20. Saedhalteh

    TEnsion only member and selenderness ratio

    Is it possible for a tension oly member to fail because of the KL/r ratio ?

Part and Inventory Search