Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. precast123

    Prestressing Abutment design

    @retired13 The deflection is mainly due to rotation at bed - abutment interface and soil settlement near abutment . You are right, I will try increasing bed thickeness. Bed is a u shape element. But still soil settlement problem will be still there. That's why I was thinking to restrain rotation...
  2. precast123

    Prestressing Abutment design

    @ingenuity can you please share the structural concept you mentioned as a sketch. Thanks.
  3. precast123

    Prestressing Abutment design

    I can calculate soil horizontal subgrade modulus and assign in SAP2000 as springs assuming it a short rigid pile. Is this assumption correct?https://files.engineering.com/getfile.aspx?folder=97cff8d8-d884-4349-8378-0a08cdfd74d4&file=Screenshot_2020-06-06-00-02-59-400_com.google.android.apps.docs.jpg
  4. precast123

    Prestressing Abutment design

    @ingenuity yes true. Its design of bed for casting prestressed girders. My first trial modelling was that for this 70m bed I have assigned springs in Z direction in SAP2000. Applied force on abutments in x direction. No 3m part below ground. The abutments deflected 30mm. I want to keep this...
  5. precast123

    Prestressing Abutment design

    Other sectionhttps://files.engineering.com/getfile.aspx?folder=407b16c5-22e4-49d8-a94b-1e49668a0fa0&file=Prestressing_Abutment-Section_2.pdf
  6. precast123

    Prestressing Abutment design

    I was designing abutments active end and passive end for prestressing. In the attached pdf 3m below ground part can be designed as short pile? Attached Structural concept will work since the load is very large approx 800 ton..? I am getting 30mm deflection for the abutments when ignoring bottom...
  7. precast123

    Stability of free standing cantilever wall with eccentric footing(safety against overturning)

    @SlideRuleEra , I was trying to create a general question. Please see attachment for actual problem. In calculating stability against overturing, i doubt I have to use 40.6kN moment due to eccentricity. For bearing stress I am sure I have to use this 40.6kN because eccentricity will cause...
  8. precast123

    Stability of free standing cantilever wall with eccentric footing(safety against overturning)

    Hi In calculating sum of overturning moment, apart from wind load or soil back fill load, should I have to consider Moment due to eccentricity of foundation? Please see attachment. I think Mw + Nxe I should consider when calculating stresses under foundation. Mw = Moment due to wind load N =...
  9. precast123

    Static load calculation of a vibrating mass

    @WARose, Thanks for your reply. I have attached the specs of roller. Centrifugal force generated is given here. Is it the total load(365 kN) the drum is transferring to the soil considering vibrations...
  10. precast123

    Static load calculation of a vibrating mass

    Thats amplitude of drum vibration.
  11. precast123

    Static load calculation of a vibrating mass

    Hi everyone, How to calculate equivalent static load due to vibrating mass. To be specific, it is vibrating roller load. Drum Load = 14.9 Ton Frequency = 28 Hz (1680 vpm) Amplitude = 0 - 2.5mm Total load on soil considering vibration will be how much? Thanks.
  12. precast123

    How wheel load is distributed on a slab under soil?

    Will this apply here? Please see attachment. http://files.engineering.com/getfile.aspx?folder=171addb0-0acd-40b4-ae8b-7dfe8330a773&file=Screenshot_2017-02-08-20-23-40-286_com.android.chrome.png
  13. precast123

    How wheel load is distributed on a slab under soil?

    Hi How wheel load is distributed on a slab buried 1m deep in soil? Is attached analysis is correct?http://files.engineering.com/getfile.aspx?folder=2a2ccc94-0131-4cf8-9100-fdb9f38d4805&file=IMG_20170208_165118.jpg
  14. precast123

    Does Precast Frame Structure(Precast columns, beams & HCS) requires expansion Joint?

    Hi I have a full precast frame structure with plan size 100 x 50 m . Does this building require expansion joints? 20 mm gap between every beam and column at corbel is not sufficient?
  15. precast123

    Concrete cover to reinforcement in Precast Cable Trenches (Buried 1m deep in the ground)

    Hi What should be the minimum concrete cover to reinforcement for Precast cable trenches as per BS Codes for a durability of 40 years? 75mm is recommended in BS if concrete is cast directly on ground for cast in place concrete.Is there any other reference in BS which specifically talking about...
  16. precast123

    Material nonlinearity

    I have used Abaqus for non linear dynamic analysis. For a frame member you can get results of Bending moment and manually calculate bending stresses(M/I * y) and plot them against time. I have always worked with Von Mises stress. Dint tried others.
  17. precast123

    Material nonlinearity

    What material non linearity you are using? Yes you have to perform time history analysis. See the attachment. Its the plot for a pipe which is axially loaded. At some point of time, the stresses becomes constant.The pipe material is High density polyethylene. You can plot Von Mises...
  18. precast123

    Material nonlinearity

    Plot Stress vs Time. At some point of time stress will become constant indicating material has entered plastic state.
  19. precast123

    Divide Frame Intersection

    Your frames aren't intersecting. Check your model. Redraw it. If its done in autocad correctly it should work too.
  20. precast123

    Water pressure on SAP 18

    You can use live load pattern instead water pressure. Load combination is what matters.