"I think you're right, the pipe rack category sounds good to me. That will get you R=3.25 then, right?"
Because the height of pipe rack is 51.5m, I think I can only use R=1.5 for my case.
For Detailing Requirements, what is the difference between AISC 360 and AISC 341? If I am designing the...
Thank you for your reply.
If I use table 15.4-2, the structure will be non-building structures not similar to buildings. Then according to 12.3.4.1, I can use rho=1.0, is it right?
But for pipe rack, in 15.5.2, pipe rack is taken as non-building structures similar to buildings, also in the...
Dear experts,
I have an important question to ask about the redundancy factor r.
We are designing steel structures only in elastic range.
According to ASCE7-05 table 15.4-1 we are considering a response factor R=1 for nonbuilding moment frames similar to buildings.
As for the redundancy...