Thank you for your reply
As you say, acid formation is a concern and the materials must be suitable. Of course I’m not sure the leaving gas temperature is going to be less than dew point temperature. Speaking about the fins, as the h of the gas is at least ten times less than that of...
Thank you, every one.
Let me explain what I intend to know and to do, a bit more.
In fact I’m going to make a double pipe heat exchanger to recover heat from the exhaust of a diesel generator as a project for my M.Sc. experimental thesis. (Of course I’m too old to be a student, but for some...
Hi
If you make a cut on the inner pipe of a double pipe heat exchanger or make a hole on it and attach a rectangular or a pin shaped fin on (in) it,(and of course, weld it) so that it is extended from inside of the pipe to it's outside,how would the fin effectiveness be changed?
I wonder if in...
thread403-400808
Hi
A garbage chute duct is simultaneously subject to positive and negative pressure at sections downstream and upstream of the garbage when it is falling down.
So I think it is not a good idea to install the exhaust fan on the upper end of it.
Generally speaking, a separate duct...
Thank you lilliput1 and Emrelug84 for your answers.
A portion of heat transfer in cooling towers is done by sensible heat transfer ; from water to air or in the opposite direction. Typical situation is not what happens all the time.There must be such relations between parameters that when...
Thank you for your reply,moideen; but my qusetion is :"Why it is not a concern?"
Suppose in a specific condition we have a 30 degrees centigrade dry bulb air.Later it get warmer up to 40 degrees.We loose some possibility of sensible heat transfer and gain some opportunity for more latent heat...
Hi everybody
In rating a cooling tower, dry bulb temperature of air is not considered. On the other hand the ratio of latent to sensible heat transfer is dependent on it. If the thermal performance of a cooling tower is considered as the sum of its ability to sensible heat transfer and latent...
RossABQ ,
It's a hydronic unit and I mean a three or two way motorized valve.I think it may be possible for a control valve to regulate flow rate for both of heating and cooling , for example both 10-20 and 10-40 gpm.Of course it seems to me that a more accurate analysis is necessary.
Hi every body
If there is no need to have cooling and heating simultaneously and if there are control valves on air handling units ,is it enough to have just a single coil for both heating and cooling?
Thank you 25362.
In central heating the pump is installed "before" or "after" heater and as you say,the expansion tank on suction of the pump.
Does it make any change in your answer?
Thank you every body
By "riser" I mean both supply and return pipes.A single supply pipe and a single return one with branches at each floor.
As racookpe1978 has mentioned I have experienced cases where flow tends to stop or tries to go the wrong way. Also as btrueblood has mentioned there were...
1 -Is there something like "pressure gradient" or "driving force gradient" in a thermosiphon system?If so,how is it drawn?
2 - Suppose a simple thermosiphon system of a heat source at bottom ,a sink at top and two risers.If there is another sink in the middle of source and sink how the system...
Thank you 25362 and Latexman.
There is a relation between Baume reading (Baume scale )and density .
But could Baume reading be considered as mass percentage? I need the information to deal with concentration of lithium bromide in absorption chillers.