Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. rainandcm

    Are there special codes governing design of wind mill foundations?

    I assume there should be codes or manuals talking specifically on wind mill structure foundations as they are subject to constant dynamic vibration. Is there anyone who is aware of any codes, manuals,or papers? Thanks. Ryan
  2. rainandcm

    OLE and CLE definitions

    How to determine the return period of OLE (Operating Level Earthquake) and CLE (Contingency Level Earthquake)? Do they vary based on different types of projects? Thanks.
  3. rainandcm

    Limit of skin frictions

    awesome paper! I've never read this kind of discussion before. Thank you BigH!
  4. rainandcm

    Limit of skin frictions

    I am trying to gather information about the maximum unit skin friction for piles. Prakash and Sharma (1990)suggested fs<=1 tsf. I also read somewhere that fs should stop increasing from 10D~20D depth. Bowles (1996) only says that fs should be considered but didn't say how. Coduto (2001)...
  5. rainandcm

    Standard proctor and modified proctor

    Thanks for such detailed explanation!
  6. rainandcm

    Standard proctor and modified proctor

    So I understand they represent different compaction energy. However, how do I know which one to use? Do types of projects matter?
  7. rainandcm

    Site classification why not correct SPT

    I agree with you that SPT is a very crude test. However, SPT correction has been used everywhere else to correlate to density, strength parameters, etc. Why not Site Class?
  8. rainandcm

    Site classification why not correct SPT

    The procedures in ASCE 7 for site classification says "Ni is the standard penetration resistance ... Without corrections". Not using corrections just don't make sense to me. Any one ever thought about this? Thanks.
  9. rainandcm

    Should I reduce soil strength for non-liquefiable soil

    If my liquefaction analysis indicate the soil will liquefy, there is enough research there to estimate my residual strength after liquefaction. However, if my liquefaction analysis indicate my soil won't liquefy (FS>1), should I also reduce my strength? FS>1 may still suggest partial...
  10. rainandcm

    Wave equation analysis

    There might be a situation where you have to have enough energy to get the pile in. If set the stroke too low, the blow counts may go very high. Can this situation happen?
  11. rainandcm

    Wave equation analysis

    I struggled a lot on performing wave equation analysis. I read lots of material but still remain in confusion. I want to post some of my understanding and questions here and hope somebody can enlighten me. I'd really appreciate your help. There are three types of analysis to be performed, and...
  12. rainandcm

    Ground Resistance in Permafrost

    I am a geotechnical engineer and been asked to provide ground resistivity test on a permafrost site in Alaska. I've never done this kind of work so I wanna make sure what I am going to do will be correct. I will be using 4-pole Wenner method. I am planning to vary my probe intervals from 5 ft...
  13. rainandcm

    Subgrade modulus for multiple layers

    Thanks everyone. This was actually for a concrete pad (16'x40'). Ron said "treat them separately". I am not sure what this means. My structure guy would only ask for one value for his analysis.
  14. rainandcm

    Subgrade modulus for multiple layers

    Typically the recommended subgrade modulus values are for one type of soils, say compacted gravel, stiff clay, etc. I happen to have a case that I will have 2 feet of compacted gravel sitting on medium-stiff clay. What is the best way to estimate a good subgrade modulus for this case? Maybe...
  15. rainandcm

    Estimating c and phi for Overly Consolidated clay in drained condition

    Thanks everyone. You guys had some really good suggestions here. I guess the conclusion I am getting at is that design based on the virgin curve with c=0 and phi.
  16. rainandcm

    Estimating c and phi for Overly Consolidated clay in drained condition

    Hello, I ran into overly consolidated clay and I need to provide drained strength parameters. Triax is not available. I got Atterberg, Vane Shear, Pocket Penetrometer and SPT. All my reference only provide phi for Normally consolidated clay. For Overly consolidated clay, they only say things...
  17. rainandcm

    Select Design Undrained Shear strength in clay with varied Su for strip footings

    Thanks. I think the biased design line with a few points lower should make sense. Thanks!
  18. rainandcm

    Select Design Undrained Shear strength in clay with varied Su for strip footings

    I had a bunch of in-situ testing that gave me varied Su for clay soil, with values from 1000 psf to 4000 psf. If I am using strip footing, it seems to be really conservative to simply use the lowest value. I think strip footing should be able to bridge over the weak spots, but I couldn't find...
  19. rainandcm

    How to be a successful geotechnical engineer

    I am a geotechnical engineer but not a successful one. I have a MS degree and just got my PE recently, which obviously didn't help much in how I feel about myself doing my work. I found that Geotechnical engineering is always challenging. Not much codes to follow, a lot of analysis instead of...