Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Mechanical_Gau

    Water Capacity

    @racookpe1978 Its Horizontal
  2. Mechanical_Gau

    Water Capacity

    @LittleInch: Hi and sorry for delay.. I got what you said, well explained. And you are right abt "1 litre of water will weigh the same as 1.96 litres of propane." I have nailed it. I need to have water capacity for the safety distance. Safety distance is categorized on the basis of W/C. Thank...
  3. Mechanical_Gau

    Water Capacity

    @racookpe1978 This is Internal Diameter. This is perfect Hemisphere. At least some empirical formulas will also do. We know that 1 liter = 1.96 Kg of propane, hence using simple arithmetic converting the same in liters. Further comparing the same with Water. (But i am not sure if its correct)...
  4. Mechanical_Gau

    Water Capacity

    Hi LittleInch 1 MT = 1 Metric Ton Unit in Metric System. I want to check Water Capacity at 100% tank filled. Whereas i propane/LPG is going to be filled at 80-85%, but that is not the case i need to check for Water. Low level will be 20%. For Eg:- If tank is 50 MT and Radius is 1.85 meters...
  5. Mechanical_Gau

    Minimum required thickness

    Refer UG-27. Let me tell you, thickness does not depend on what fluid you are using, its solely depends on your Pressure, MOC and dimension. In case of UG-16(b), those fluids even if exposed to ambient will not have any ill effect, hence those are standard thickness provided by ASME. Please...
  6. Mechanical_Gau

    Water Capacity

    Hello Friends I have very basic simple question to ask. How much water capacity does 1 MT storage tank will have(considering dish end as hemispherical)ie. 1 MT storage tank will contain how much liters of water. In that case how much W/C in 50 MT ? Your kind help will be appreciated.
  7. Mechanical_Gau

    ANSI Flange 300# Failing at Design Pressure

    Hello friends and MJCronin, I am sorry for the delay. I really appreciate your answer for the same it has however increased my knowledge. The reason that it was failing because it was not sustaining on that thickness. hence 300# flange was failing and 150# was passing. That is all i can say...
  8. Mechanical_Gau

    ANSI Flange 300# Failing at Design Pressure

    @SnTMan .. The problem was it was passing on 150# flange but not for 300#
  9. Mechanical_Gau

    How can the material impact test temperature be set in PVElite 2017 ?

    Hi Vessel Fred Sorry for the delay. To set the material on Impact Test on PV Elite, all you have to do is --> While selecting material there are 3 dots besides its selection. --> Go for "If normalized or quenched and tempered option" so that your material gets shift to curve D --> Check the...
  10. Mechanical_Gau

    ANSI Flange 300# Failing at Design Pressure

    Hello Friends, Thank you very much for all your replies. The problem got solved. I have increased the thickness considerably with approval and things are now fine. Thank you once again. @MJCronin SS --> Screen Shot BTW MJCronin, why in America do you take particularly 250 psi ? is there any...
  11. Mechanical_Gau

    ANSI Flange 300# Failing at Design Pressure

    According to Indian Standards it is imperative to select 300# Flange for Propane and LPG service. Kindly help me over.
  12. Mechanical_Gau

    ANSI Flange 300# Failing at Design Pressure

    Hello Friends, We are designing Propane Mounded Storage Tank for Water Capacity of 119,000 Liters. Here are the following details with the SS. Working Pressure - 12 kg/cm^2 (171 psi) Design Pressure - 21.356 kg/cm^2 (304 psi) Corrosion Allowance - 1.5 mm (Is it fair to have 1.5 mm (0.059") or...
  13. Mechanical_Gau

    Re Design of Mounded Bullets on PV Elite

    Hello Folks I am new in this field and need some expert guidance regarding Mounded Bullets My queries are 1) Can we design Mounded Storage tank in PV Elite? 2) If yes, then what precaution one needs to take while designing the same? 3) What special precaution needs to be taken when its...