Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Hakim Eng

    Proportional Valve issue

    But the problem happens with several cylinder with the same hydraulic system i mentioned. Could you please recommend me a documentation that describes the principal of operation of these proportional valves. Thank you so much for your help
  2. Hakim Eng

    Proportional Valve issue

    Hello guys, i have a linear hydraulic cylinder controlled by a plc through 4-20 mA proportional valve. The whole hydraulic system composed of: - proportional valve. - blocking valve. - pressure switch " to ensure oil presence" - a position transducer. when trying to move the cylinder up/down it...
  3. Hakim Eng

    Sinamics G120C PN

    Hello guys i have a network f G120C PN drives connected via Profinet cables to an ET200SP plc. i already have the project of the drives created by Starter software and is saved in my pc knowing that the drives are in factory settings. how to proceed to download the project to the drives ? is...
  4. Hakim Eng

    Beckhoff BC9050 PLC

    Hello guys, i need help please, i have a Beckhoff BC9050 PLC connected to Proface HMI. i connected to the controller through TwinCat 2 but can't upload the whole program. do i need to install the OPC server in my pc to have access to the whole program ? if so which version do i need ? Thanks in...
  5. Hakim Eng

    Sinamics G120C PN Drive

    Help Request Hello Guys i have a Sinamics G120C PN error, when trying to execute the Start Command through the Starter software it gives the following error Message: "the switch-on disable of the drive is active " in addition to this, the diagnostic buffer shows that there is a missing enables...
  6. Hakim Eng

    Danfoss ETS Valve

    Hello Team, i have a Danfoss ETS 25 34G4203 valve with 12V DC located 20 meters away from the EKC 316A Controller, and the cable is only 8 meters length, in addition to this i have a cable filter AKA 211. Can i use a shielded cable of 20 meters instead of the original cable ?
  7. Hakim Eng

    Voltage drop Calculation

    Hello guys, i have to connect a generator of 1125 KVA of 400 V line to line 50 Hz frequency with an Automatic Transfer switch. the ATS is located 15 meters away from the generator, the company that made the conception of the project implies that we have to use a cable of 12 x (1x300 ) + 4x...
  8. Hakim Eng

    electrical balance system

    Hello Guys, please i need help, i have a balance " Commander-N CE care weighting system" with it's printer inside a panel, my question is: - wich type of the signal sent from the weighting cells board to the printer ?. - i have the length of the cable about 8 meters with cable section of 4x0.35...
  9. Hakim Eng

    Electrical Cable section calculation

    Thank you so much guys for your replies and precised answers, i am an Automation Engineer not Electrical Option, these are the main characteristics of my situation: - the motor is three phase motor in star connection with power factor of 0.8 indoor installation. - 50 Hz frequency with 400 v...
  10. Hakim Eng

    Electrical Cable section calculation

    Hello guys, i have a 15 KW three phase motor situaded at about 600 meters away from the power source, which cable section do i need to use ? thanks in advance
  11. Hakim Eng

    TIA PORTAL V13

    the problem is solved, Thank you
  12. Hakim Eng

    TIA PORTAL V13

    i would like to thank you so much for your reply, now i uninstalled TIA V13 correctly, and when i want to re-install again, the directory installation path is fixed to D\TIAPORTAL; and don't have possibility to change the path to partition C or E of my hard drive. is there any suggetion please...
  13. Hakim Eng

    TIA PORTAL V13

    Hello guys, could you please guide me to remove TIA PORTAL V13 Completely from my pc , i uninstalled it through the control panel, but it still exist within the programs. thanks in advance
  14. Hakim Eng

    Magelis HMI Configuartion

    Hello Guys, How to set-up the HMI ip address for Magelis protecred with a password ? Best Regards
  15. Hakim Eng

    SEW Servo drive with plc M340

    yeah i will, Currently i am in holidays, once i get back i will return you the feedback 😊
  16. Hakim Eng

    SEW Servo drive with plc M340

    Thank you so much, i will check it soon.
  17. Hakim Eng

    SEW Servo drive with plc M340

    Maybe we are confused using this keyword homing, just forget about it, - a sin/cos encoder is connected to the DEH11B card of the servo drive. Can i configure it in an openloop control ( neglect the encoder ) and just use a limit switch or a photocell to ensure that the product reaches the...
  18. Hakim Eng

    SEW Servo drive with plc M340

    Hi, yeah i am agree with you, the homming is like the initial position, in my case i have a rolling chain with product on it, once it travel from initial position to target position it has to be re-initialised.means every time the motor turns 1709 and start again from zero. i hope it can be...
  19. Hakim Eng

    SEW Servo drive with plc M340

    Hi, I would like to thank you for your reply, and this is my situation - SEW Movidrive MDX61B, programmed with IPOS. - Fixed speed with a fixed target position. -controlled via plc M340.using i/o scanning via ethernet. - Homing means moving toward the target position ( when target position...
  20. Hakim Eng

    SEW Servo drive with plc M340

    Hello guys, Please i need help about SEW Servo drive controlled via SBus & Field Bus Modicon M340 PLC. The problem is, when the motor reaches its desired position, the homming request still be on and the status word.0 ( motor is turning ) is sent to plc in a flashing manner (On/Off). What could...

Part and Inventory Search