  1. nasim123

    Differences between PVZV and PVV

    Dears Can you pls explain the differences between PVZV and PVV? Thanks
  2. nasim123

    Steam service PSVs testing on Air Test Stand

    Dears ASME SECTION VIII D1 2009, UG-136(d)(4) states " Necessary corrections for differentials in popping pressure between steam and air shall be established by the Manufacturer and applied to the popping point on air." Is it mandatory to make the CDTP corrections while testing the Steam...
  3. nasim123

    PSV CDTP calculation based on operating temperature or relieving temperature

    Dear Avalveman, While calculating the CDTP, we are referring the operating temperature. If the operating temperature is more than 120 Degree F, then we need to multiply temperature correction factor with set pressure, then only we will get the CDTP. Except Crosby design pzvs, we are referring...
  4. nasim123

    PSV CDTP calculation based on operating temperature or relieving temperature

    Dears I need your advice pls As per API RP 520,(page 48) the temperature correction factor (multiplier) is typically required when the relieving temperature exceeds 250°F. However in Dresser PSVs(Consolidated PSVs)they are referring the operating temperature not relieving temperature. In...
  5. nasim123

    PSV online Testing limitations

    Hi, Dresser is doing the online testing from valve size 1" onwards. While conducting the online test, you can verify only set pressure, No leak test or back pressure test. Most of the companies prefer to test steam service valves, not process psvs. Thanks Nasim
  6. nasim123

    PSV Outlet Flange mismatch

    Dears Find attached reply from the PSV Manufacturer. Thanks a lot for your support " This exceed is in accordance with API Standard 526, Section 2.4. Dimensions:" “For some valve designs, the inlet raised face height may substantially exceed the nominal dimension specified in ASME / ANSI...
  7. nasim123

    PSV transportation after calibration

    Dears We would like to test & calibrate our new psvs in RV shop, which is more than 180KM far from our plant. As per code/API, is it acceptable? After calibration, how many kilometer transportation is acceptable(by road)? Can we have your advice pls Thanks
  8. nasim123

    PSV Outlet Flange mismatch

    PSV SIZE: 2"-600# X 3"-150#
  9. nasim123

    PSV Outlet Flange mismatch

    Dears Find attached photograph for the PSV outlet mismatch. Your comments pls. If the outlet is not matched with outlet piping, what are the issues we may face in future. Also if the inlet flange is not matched what are the issues we may face in future. Your valuable comments are really...
  10. nasim123

    ASME SEC 1 PSVs set point

    Thanks Avalveman for your support
  11. nasim123

    ASME SEC 1 PSVs set point

    Dear avalveman Thanks for your feedback. "V" stamped ASME Section 1 Safety Vales are installed in our boiler separately.(One Drum having 2 SVs with different set point 45 & 49 KGc/cm2g - 1st floor). 3rd PSVs is located in the ground floor with 49Kg/cm2g set pressure. During in-place test(on line...
  12. nasim123

    ASME SEC 1 PSVs set point

    Dears We have 3 PSVs in our Boiler and the boiler operating pressure is 40Kg/cm2g. Can you please inform us, at what pressure we need to set each safety valve. As per code how much gap we need to keep on each psv? Presently it is 1st PSV - 45Kg/cm2g, 2nd PSV - 49Kg/cm2g 3rd PSV - 49Kg/cm2g...
  13. nasim123

    Bellows design PSV Bonnet vent

    Thanks bevjones2009. Yes, we not plugging the bellows design pzvs bonnet vent. Field operators are asking us, if we plug the bellows design pzvs vent, what will happen?. I would like to have any other answers from the experts other than I mentioned in the question. I received beautiful &...
  14. nasim123

    Bellows design PSV Bonnet vent

    Thanks Don1980 for your reply
  15. nasim123

    Bellows design PSV Bonnet vent

    Dear All As per psv procedure, we must keep the bellows design psv's bonnet vent keep open or piped to a safe location. If we plug the bellows psv bonnet vent, what will happen? How it affects the psv performance? 1. As per code, we should not plug the bellows design psv's bonnet vent, it is...
  16. nasim123

    Gate valve stem in Horizontal position

    Thanks a lot for the reply
  17. nasim123

    Gate valve stem in Horizontal position

    Dears As per Saudi Aramco Standard SAES-J-600 States " When gate valves are used as block valves for Pressure safety valves,they shall be installed with the stem horizontal or sloping down away from the relief valve to keep the gate from falling off and blocking the flow.". What is the logic...
  18. nasim123

    Section 1 Boiler Valve in-place test(on line Popping test)requirement for PSVs

    Dears If we have section 1 Boiler PSVs,even if we calibrate the PSV in the shop, we need to conduct in place test(on line popping test) at site. What is the reason behind this requirement. Why a section 1 Boiler PSV needs to test at shop & then test at site? Awaiting your feedback Thanks Nasim
  19. nasim123

    Set Pressure Tolerance for Steam Safety Valves

    bljnv.. thanks for your swift response. In Saudi Aramco, PSVs are called PZVs.
  20. nasim123

    Set Pressure Tolerance for Steam Safety Valves

    Dears i need your advice for the steam service safety valve tolerance. If the PZV design is section 8 and the service is steam we need to follow Table 2 for the set pressure tolerance or Table 1. Table 1 – Tolerances for Set Pressures of Pilot/Safety Relief Valves (In English Units to Conform...