    Anti vortex baffle in tank

    yeah that is what i noticed too. The m_dot was provided to me. Fr is the dimensionless Froude number. S is the submerged depth and the formula of submerged depth was from a piping text book.
  2. Shamoon85

    Anti vortex baffle in tank

    Hello, I want to discuss some things about vortex breaker device installed at the fuel and oxidizer tank outlet. I have to do a study project in which I am supposed to add this device on outlet of a tank which is 200mm. I wanted to know that is there a thumb rule for device height; while...
  3. Shamoon85

    Anti vortex device at tank outlet

    Ok, with regard to the size of the tank, if I have to increase the size of the tank by twice, is there any rule or law to scale the vortex breaker too. Smaller one has exit dia 110 mm while larger one has exit dia of 200mm.
  4. Shamoon85

    Anti vortex device at tank outlet

    @LittleInch Do you have any idea, if anyone has done CFD on it? which hydraulic institute are you talking about?
  5. Shamoon85

    Anti vortex device at tank outlet

    does anyone have done CFD of vortex baffles?
  6. Shamoon85

    Anti vortex device at tank outlet

    @bimr, my sincere apologies. I couldn't still find it.
  7. Shamoon85

    Anti vortex device at tank outlet

    @bimr : where is Figure 4?
  8. Shamoon85

    Anti vortex device at tank outlet

    what should be the height of the blades (vanes)?
  9. Shamoon85

    Anti vortex device at tank outlet

    with reference to the above thread. I want to dicuss some things about vortex breaker device installed at the outlet. I want to add this device on outlet of a tank which is 200mm. I wanted to know that is there a thumb rule for device height; while device vanes are usually mentioned as 2/3 of...
  10. Shamoon85

    thread124-156148 with reference

    thread124-156148 with reference to the above thread. I want to dicuss some things about vortex breaker device installed at the outlet. I want to add this device on outlet of a tank which is 200mm. I wanted to know that is there a thumb rule for device height; while device vanes are usually...