Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. RHT2020

    4-ply 2x_ built up beam/column nailing pattern

    Hi, I have a project have 4 ply 2x10 built-up beams/columns. Instead of full length nails penetration in the 4 ply from opposite sides, any chance we can nail 2 ply first and another 1 ply each face with 3" nail to make it 4 ply built up beam/column? Which part of design code I can find relevant...
  2. RHT2020

    Top rebar in structural slab in unheated building.

    Jayrod12, footprint is 14x20feet. my slab is 7" with 18" deep grade beam around.
  3. RHT2020

    Top rebar in structural slab in unheated building.

    retired13, it is structural slab. I don't think bottom rebars can be saved.
  4. RHT2020

    Top rebar in structural slab in unheated building.

    Hi retired13, it is a shed building in rural area with concrete pad and wood frame building on it. Hi atrizzy, I have grade beams at the perimeter of building between piles. I have L dowels from the grade beam to the slab all around top. Thanks.
  5. RHT2020

    Top rebar in structural slab in unheated building.

    Hi, I am designing a "doghouse" building with structural slab on void form and supported by pile system. The building is unheated year round. I have designed the slab with bottom reinforcement and slab thickening at the perimeter of building. Do you think I need top rebar in the slab for any...
  6. RHT2020

    Metal deck connection Welded VS pined

    Hi, I am designing a building for heavy overhead cranes(2 x 175 T). It is a conventional steel building with double column for crane runway beams. Each bent is designed as moment frame and I have vertical bracing in runway direction at every 4-5 bays. Also I have roof horizontal bracing to tie...
  7. RHT2020

    Safety Factors - outrigger platform design

    It will be like "PERI RCS MP materiel platform" to move materials and formworks to high rise building.
  8. RHT2020

    Safety Factors - outrigger platform design

    Hi, I am designing a temporary outrigger platform for a Multi - story building. I am wondering what is safety factor I should use for the platform floor and outrigger beam design? It is lightly loaded. S.F of 2 is good enough? Any codes and standards I should refer to? I don’t think outrigger...
  9. RHT2020

    2-150 Ton OH Crane Supporting Structure

    Hi, I am desiging a building with 2-150 Ton overhead cranes and 3 ton jib crane. Columns spaced at 6.1m, crane bridge spans at 25m, roof is 20 m height and oH crane located at 11 m height.It is my first time to design crane supporting structures for this kind of monster crane I have following...
  10. RHT2020

    Build up steel column

    Hi, I am designing a 10 meter free standing build up column to support signs on the column top. In my design, I checked single wide flange column worked for lateral torsional buckling strength. I added second wide flange column (Side by side) for serviceability. Can any body tell me how often...
  11. RHT2020

    Two way slab - reinforcement requirement at middle strip

    Void form will be placed under the slab. What kind of anti-crack reinforcemen I should specify? Welded wire mesh are good option?
  12. RHT2020

    Two way slab - reinforcement requirement at middle strip

    Hi, I am new here and hope to get some suggestions on the two way slab design. I am designing a single story car dealership here in Canada (CSA codes). We decided to use structural slab for this building due to expansive soil on site. We layout concrete pile at 4.8x4.8m and slab is 150 mm thick...