  1. mcm1209

    pressure testing an altered piping spool

    We used a pre-tested pipe to replace small things like a spool piece. No need to re-test the spool piece as long as evidence of test on pipe is present and acceptable by customer.
  2. mcm1209

    Pneumatic Test update to old thread.

    I do hope he worded that wrong. Unfortunately in this day in age, some are rewarded by "finishing" the project ahead of schedule or on time. Some using sketchy means to do it.
  3. mcm1209

    Pneumatic Test update to old thread.

    It was a very hard decision to up and leave a very well paid job and not have another lined up. But everything happens for a reason, found a better paying job that respects my experience. Thanks for the compliments, just doing what was right.
  4. mcm1209

    Pneumatic Test update to old thread.

    Thanks Resigning was the best thing I could have done. A month later I was interviewing and accepting a job with a major oil and gas company. I am now the customer and I found it amusing that their sales people would call on me, to see if we had something they could help us with. Guess how many...
  5. mcm1209

    Pneumatic Test update to old thread.

    thread481-348164 At the time this was happening I was getting conflicting numbers from the PM in charge. I was never able to speak with the customers engineer in charge of the job. I resigned 2 weeks after this thread was started. The test did happen with no incidents the week after I posted...
  6. mcm1209

    Pneumatic Test

    Because of the time I was given to do this test. I told my superiors (VP of the company) that I will have no part in this test. They have a third party company that will be doing the test. Frac tanks I work with are 20,000 gallons. 500 BBL's
  7. mcm1209

    Pneumatic Test

    As far as approval! Only approval we have is from our client telling us "proceed" this morning. No engineering has been conducted. Project manager is running numbers right now is what I'm being told. 7 miles 20" X65 .375 I agree that the number of crossings and proximity to homes etc... is...
  8. mcm1209

    Pneumatic Test

    My main concern is the time to "engineer" this pneumatic test. I am no way an engineer but I know my profession and from being involved in them before, i know its something you just don't decide to do overnight. Reason for Pneumatic test is lack of space for 32 frac tanks. Of course cost plays...
  9. mcm1209

    Pneumatic Test

    Key questions are: Are there any people in the potential "blast" zone? Yes, line is close to residences Do you cross any public roads? Yes, at least 10 road crossings Can you keep everyone out of a zone about 15m either side of the pipeline for the duration of the test? in all honesty, unless i...
  10. mcm1209

    Pneumatic Test

    Guys I am working for a pipeline construction company. I have been in the process and pipeline services since 1999. I joined this company to start a hydrotest division. We are being asked by our customer to conduct a pneumatic test of 7 miles of 20" pipeline. Test pressure is somewhere in the...