Dear All,
If I need to have a PSV that is not available in API 526 selection table i.e. N size orifice with inlet rating of 2500# and outlet rating of 300# but a PSV manufacturer quote they can supply such PSV.
My question as below:
1.Does that PSV still can qualified for the necessary ASME...
Thanks a lot avalveman for such a clear explanation. Really grateful for that.
I hope you may provide further clarification with regards to the hydrostatic testing.
As there are 2 type of nozzle for PSV i.e. full nozzle and semi-nozzle.
While the semi-nozzle design will exposed the valve...
Dear All,
For PSV shell test as per ASME VIII Div 1, UG-136(d)(2) Hydrostatic Pressure Test specify to perform the test at 1.5 x design pressure of the part.
For PSV body, e.g. 900# inlet flange x 300# outlet flange, should we test it to the 900# or 300# rating for the shell test?
If we test...