Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: bduff
  • Order by date
  1. bduff

    Rivets - ASTM A502 - Grade 1, 2, or 3 Suppliers

    Can anyone recommend a company that can supply Countersunk Rivets that meet ASTM A502 - Grade 1, 2, or 3? Thanks in Advance!!
  2. bduff

    Cold Forming Countersunk Holes

    Thanks for all your replies and I agree with all of them. I knew this was a long shot but just wanted to put it out there just in case someone had done this previously. Currently we do this process by machining and were just looking for ways to cut time without creating a hot work plate (for...
  3. bduff

    Cold Forming Countersunk Holes

    I am investigating a manufacturing process in our shop where we are cold forming (pressing) the countersink detail into the plate rather than machining it. The countersink is for a 3/4" bolt and a 3/4" plate. Problem is the plate is splitting to the end of the plate which is 1.625" from the...
  4. bduff

    Closed Cell Foam Expansion Device

    I have a hydraulic device that operates at very low pressures. To date, it has been completely filled with oil and is then sealed (no hoses, lines, etc are present). Ambient temperature conditions are causing the oil to expand which increases the internal pressure and has caused the device to...
  5. bduff

    Pressure Change Due to Varying Temperature of a Closed Cell Oil Tank with No Expansion Chamber

    Thanks Everyone!!! Do you know of a good source for Bulk Modulus / Compressibility Factors and also Volumetric Coefficients of Expansions for fluids??
  6. bduff

    Pressure Change Due to Varying Temperature of a Closed Cell Oil Tank with No Expansion Chamber

    I am trying to calculate the pressure change due to temperature fluctuations of an incompressible fluid (Transmission Fluid) inside a closed reservoir tank. According to an equation I have found, h2 - h1 = c(T2-T1) + v(P2-P1), provides property changes of incompressible fluids where: h =...
  7. bduff

    Solid 1" Rivet Installation

    During rivet installation, I will have a substantial amount of clearance on both sides. Any excess material on the tail end that protrudes will be ground flush with the edge. Once installed in its final resting place, clearance will be limited and that's the reason for choosing countersunk...
  8. bduff

    Solid 1" Rivet Installation

    I am in need of some assistance on where to find a rivet tool, press, or hammer that is capable of finishing 1" solid steel countersunk head rivets. The tail will also be countersunk as I have no clearance for any protruding material on either side. These are 1" rivets with a finish length of...
  9. bduff

    Cutting Fiberglass Cloth

    I am inquiring into if any of you have ever cut holes into a piece of fiberglass cloth. I need an efficient way of doing so in a production environment prior to bonding the cloth with epoxy. I have inquired to our local Laser Cutting Shop to see if they can do so but I'm not confident this...
  10. bduff

    Solidworks Simulation Pros & Cons

    Thanks, definitely planning on going to a training class when we purchase the software.
  11. bduff

    Solidworks Simulation Pros & Cons

    I am pushing to have a few seats of Solidworks Simulation Professional purchased for my engineering group. I would like to hear your experience with the software. What problems have you run into? Would you reccomend it to a new user? I have used Solidworks for years so the user interface...
  12. bduff

    Gear Pumps & Fluid Viscosities

    hydtools, Thanks for your reply. Current power unit configuration is 2HP @ 1 GPM rated for 3500psi. A cooler would definitely solve the problem but a cooler is just not an option in its enviroment. 68 grade was just something I could get my hands on quickly. I'm having a little trouble...
  13. bduff

    Gear Pumps & Fluid Viscosities

    Thanks guys. I agree that I am asking alot of the pump and could be that I am just asking too much. I believe I will change the Top Limit Pressure to around 2500 psi and see how the system responds. To give you a little more background, the system is operating a 2" Bore Cylinder 4" in stroke...
  14. bduff

    Gear Pumps & Fluid Viscosities

    Ok guys / gals, I am currently having problems with Hyd. Fluid Viscosities effecting gear pump performance. Background of System: Pump Charging Accumlator to 3000 psi with Pressure Switch in line to turn pump off. Accumlator Discharge every 36 seconds. Repeat Process. Background of...
  15. bduff

    Hydraulic Piston Velocity through a Known Fluid

    Thanks. Sounds like a reasonable approach. I'll do the calcs and then do some actual testing once the prototype is complete. Thanks again!
  16. bduff

    Hydraulic Piston Velocity through a Known Fluid

    Any Help you could provide with the following question would be greatly appreciated. Problem: I am trying to determine the velocity of a piston through a hydraulic cylinder. (Rod goes through the piston with a gap of known area to allow allow the fluid to flow from one side of the cylinder to...