  1. nampar

    Shotpins in Special Moment Frame Beam Protected Zone

    Thank you all for your inputs. I will use your suggestions as a means to try justify that the shot-pins penetrations do little impact/alter the structural intent i.e. hinging at the face of column.
  2. nampar

    Shotpins in Special Moment Frame Beam Protected Zone

    Hi, I am currently working on a project where the contractor has mistakenly punched about 6 shot-pins in the bottom flange of an existing SMF beam within the protected zone. It is a Wuf-w connection. This SMF must have been installed a few years back and we do not have calcs or dwgs for the...
  3. nampar

    Original SEOR not available and SSK stamped by other engineer - Buena Park, CA

    Hi All, At one of my friend's house, the city inspector asked the contractor to have certain discrepancies approved by a structural engineer. Now the SEOR who stamped and produced the drawings is not available and there is an extreme urgency to finish off the work and have it approved. I would...
  4. nampar

    Headed Bars v/s standard reinforcement codal requirements per ACI 318-19

    Hi All, I have a question that involves substitution of standard reinforcement with headed bars for a beam. Please refer to the attachment for code section (ACI 318-19). • For beams with regular reinforcing; we generally use 25.2.1 for rebar spacing and clear cover of 1.5” if it is an interior...
  5. nampar

    Post Tension Transfer girder precompression force and tensile stresses

    Hi everyone, I need to design a 60ft span transfer girder supporting a column that sees loads from nine stories above. My girder c/s is 66in wide x 76in deep. My tensile stresses are going beyond 12sqrt(f'c) i.e. in the cracked zone. Also my P/A is around 750psi. I am using a cracked section...
  6. nampar

    Site Stabilization Piles in Landslide zone

    I have site stabilization piles in landslide zone. I have 2 rows of piles and am analyzing it as a moment frame system still I and am getting a 5 ft dia pile with insane amount of reinforcement. Has anyone met with a similar condition? I need some help brainstorming the solution.